R E P A I R S

8.6.5 Removing core units

Both core units can beremovedthesame way.

For each core unit loosen 1 remaining screw (41, oval shaped head) at the bottom side of platform.

For complete removal of a core unit proceed as follows:

4.Disconnect 2 insulated adapter plugs (15, phase and neutral wire).

5.If a ground wire (15, part of thermoblock) is present, disconnect flat receptacle.

6.Open protective case (69) with screwdriver and disconnect connection cable (b).

7.Pull out core unit from platform slightly to disconnect synchronization cable plug (a) from electronic control board.

8.Pull off both hoses from angled H­connector (65).

9.Lift core unit out of platform.

After the first repair step the core unit can be pulled out of the

platform slightly (with still connected hoses and wires). Now the covers of the core unit can be removed.

The flat receptacleon the ground wire has a special connector

latching (see detail). Press down lever at first, then pull off receptacle.

Citiz service manual

89

Page 89
Image 89