R E P A I R S

8.5.5 Replacing power cord

Remove 2 insulated faston receptacles (55) from mains switch (54).

If present, disconnect ground wire (15, part of thermoblock assembly).

Unlatch cable bracket (56) with screwdriver.

Use a pair of flat pli­ ers to pull off insulat­ ing sleeve with recep­

tacle.

The counterpart, a flat receptacle, has a special connector

latching (see detail). Press down lever at first, then pull off receptacle.

The cable bracket is under tension. There­ fore, hold the cable

bracket with your finger when unlatching it.