To simplify matters, the model Citiz with core unit "C­range" is used to exemplify through­

out this chapter.

Symbolic illustration of function test equip­ ment.

F U N C T I O N T E S T S

9 FUNCTION TESTS

9.1Safety instructions

Some function tests are performed with an energized, partly opened coffee machine.

Danger of electrocution!

Mains voltage inside the coffee machine.

Do not touch any live part while performing tests.

Danger of burns!

Hot parts and water under pressure inside the coffee machine. Do not touch any hot parts while checking for leakages! Always wear protective goggles.

9.2Required equipment

9.2.1 Overview

1)

Pressure gauge

4)

Electronic thermometer

 

(EFR no. 16195)

 

(or digital multimeter suitable for temper­

2)

Citiz pressure gauge adapter

 

ature measurement)

3)

Digital multimeter

5)

Timer

 

(for NTC temperature sensor test)

6)

Measuring beaker

 

 

7)

Test equipment for protective earth con­

 

 

 

tinuity test and protective insulation test

130Citiz service manual

Page 130
Image 130
Nespresso EF483/484, EF485/486, EF487/488 manual Function Tests, Required equipment, Overview