F U N C T I O N T E S T S

Do not damage inside coating of milk frother jug with

the probe tip.

Additional test for coffee machine

Citiz & milk:

1)Touch upper metallic part of milk frother with red test probe.

2)Press "measure" button and read off displayed resistance.

3)Repeat measurement on another metallic spot of milk frother for verifica­ tion.

The resistance must be lower than

0.3Ohm.

4)Fill in measured value(s) in a test report.

9.8.4 What to do if the protective earth continuity test fails

Check/measure ground connection in platform (refer to page 75).

Check/measure ground connection on milk frother connector (refer to page 73 and page 124 for wiring diagram). Replace milk frother connector if necessary.

Clean ground contact on milk frother. Measure resistance between ground contact and jug of milk frother. Replace milk frother if necessary.