The hoses can remain on the water tank connector.
Use a pair of flat pli ers to pull off insulat ing sleeve with recep
tacle.
Theflat receptacle on the ground wire has a special connector
latching (see detail). Press down lever at first, then pull off receptacle.
The cable bracket is under tension. There fore, hold the cable
bracket with your finger when unlatching it.
R E P A I R S
8.4.4 Replacing power cord
•Remove water tank connector from platform first (see page 59).
•Remove insulated faston receptacle of phase wire from mains switch (54).
•Disconnect adapter plug of neutral wire (15).
•If present, disconnect ground wire (15, see detail).
•Unlatch cable bracket (56) with screwdriver.
62Citiz service manual