The hoses can remain on the water tank connector.

Use a pair of flat pli­ ers to pull off insulat­ ing sleeve with recep­

tacle.

Theflat receptacle on the ground wire has a special connector

latching (see detail). Press down lever at first, then pull off receptacle.

The cable bracket is under tension. There­ fore, hold the cable

bracket with your finger when unlatching it.

R E P A I R S

8.4.4 Replacing power cord

Remove water tank connector from platform first (see page 59).

Remove insulated faston receptacle of phase wire from mains switch (54).

Disconnect adapter plug of neutral wire (15).

If present, disconnect ground wire (15, see detail).

Unlatch cable bracket (56) with screwdriver.

62Citiz service manual

Page 62
Image 62