3.5 Short “LEASH” probes

The standard product includes 4 “LEASH” probes connected to this Interposer product. These short probes are soldered directly onto the interposer and interface the Interposer to the Passive probes that connect to the logic analyzer. These “LEASH” probes are to allow the user to easily install and remove the Interposer product in their system with out the added weight of the passive probe attached. There may be other probing options in the future. Contact Nexus for any updates.

Figure 1 below shows the location on the Interposer of the LEASH probe connections.

Location of HCD connectors, right under metal compression plate, and probe tip board:

S_C3/2

 

M

A3/2 A1/0

PRB2

PRB2

PRB1

PRB2

Figure 1 – Drawing of Interposer with probes attached

The four (4) each, 1 foot long, “LEASH” probes that are soldered onto the Interposer are in turn connected to either a NEX-PRB1X-T or NEX-PRB2X-T probe. The NEX-PRB1X-T or NEX- PRB2X-T probe in turn connects to the input of the logic analyzer modules. The connection between the LEASH Probes and the logic Analyzer is a Samtec connector with a pin out as shown below on the LEASH probe. Refer to 3.2 to determine if a NEX-PRB1X-T or NEX- PRB2X-T connects to each LEASH probe.

DDR3THIN-MN-XXX

15

Doc. Rev. 1.11