5.0 CONFIGURING FOR READ / WRITE DATA ACQUISITIONPrior to configuring your NEX-DDR3INTR-THIN support package it is strongly recommended that Appendix A (“How DDR Data is Clocked”), section 5.4 (“Selecting DDR Read Sample Points”) and section 5.5. (“Selecting DDR Write Sample Points”) be read. This background information is very helpful and facilitates proper support configuration.
5.1 A Note About the Different Data GroupsThe NEX-DDR3INTR-THIN support software have three different areas where signal groups are defined to provide specific functionality. There are the MagniVu data groups (see Table 4) are the groups that contain raw MagniVu data. Storage data groups (see Tables 1, 2 and 3) can be seen in the acquisition card Setup window and contain the data stored in Main Memory which is used for the Listing display. Capture data groups (not defined in this manual) are the groups seen in the TLA’s Setup & Hold dialog box and are the groups used to capture data during each DDR clock cycle. The MagniVu and Capture data groups will be referred to in the following explanation on determining and setting the correct sample points to acquire Read and Write data. Please contact your local Tektronix representative for a detailed explanation of the different data group areas and what they mean.
5.2 MagniVu SignalsBecause of the design of the Tektronix TLA7BB4 acquisition cards different data groups need to be defined for use within MagniVu. Table 4 shows the MagniVu group definitions present in the B_DDR3D_2D/_2G supports. Table 5 shows the MagniVu group definitions present in the B_DDR3D_3A support.
DDR3THIN-MN-XXX | 44 | Doc. Rev. 1.11 |