ZR-6 ERROR CODES

TROUBLESHOOTING

ZR-6 ERROR CODES

LCD Panel Message

AMP NOT HI Z

EEPROM FAULT MULTIPLE MASTERS MULTIPLE SLAVES OVERLOAD PROTECTION THERMAL WARNING ZONE # LSPKR OK ZONE # LSPKR PVDD ZONE # LSPKR SHRT ZONE # RSPKR OK ZONE # LSPKR PVDD ZONE # LSPKR SHRT POWER FAILURE # 12 POWER FAILURE # 34 POWER FAILURE # 56

SPKR WIRE ERROR # 1 SPKR WIRE ERROR # 2 SPKR WIRE ERROR # 4 SPKR WIRE ERROR # 8 SPKR WIRE ERROR # 9

Correction

Internal Amplifier Error; Reboot System

Internal Processor Error; Reboot System

More than One Chassis Designated as Master

More than One Chassis with the Same Slave Name (1 or 2) Speaker Load Less than 4ohm

Speaker Load Less than 4ohm

Inadequate Ventilation

Speaker Wired Correctly in a Zone with an Incorrect Speaker Internal Amplifier Error; Reboot System

Speaker Shorted; Check Wiring

Speaker Wired Correctly in a Zone with an Incorrect Speaker Internal Amplifier Error; Reboot System

Speaker Shorted; Check Wiring

Is a fault in either zone 1 or zone 2

Is a fault in either zone 3 or zone 4

Is a fault in either zone 5 or zone 6

PVDD over voltage fault is present

PVDD under voltage fault is present

AVDD analog fault is present

Charge-pump voltage fault is present

Combination of #1 and #8 which is usually caused by Speaker Signal leaking to Earth/Chassis Ground

NILES AUDIO CORPORATION – 1-800-BUY-HIFI305-238-4373

 