Chapter 8: | |
|
|
VPD-6830-DEQ
Configuration
Before adjusting R6, the potentiometer R5 on the SBDEQ must be set to zero (turn R5 counterclockwise to its minimum adjustment value).
1.Set the Input Coupling for either AC or DC coupling using jumpers J2 and J3. See Figure
2.Set the Clamping mode on jumper J1 to either Soft, Hard or No Clamp. See Figure
3.Adjust the gain over a range of
Turn the potentiometer clockwise to increase the gain. See Figure
4.Adjust continuous equalization to the Belden 8281 using the R6
Turn the potentiometer clockwise to obtain more equalization. See Figure
5.Make fine adjustments to the
The
6.
6800/7000 Series - Distribution and Routing Products Installation and Operation Manual | 81 |