Chapter 1: AES-6880 AES/EBU Digital Audio Distribution Amplifier Module

Error Detection and Reporting

 

 

User Configurable Contact Closure Alarm Indicator

A red LED mounted under the Error LEDs on the front edge of the DA card provides a user-configurable Contact Closure alarm indicator. When this LED is on, the external alarm contact closure is asserted, indicating an error has occurred.

Jumpers J3A-F are used to determine which error conditions will trigger the alarm (see Figure 1-4 below). When all of the jumpers are in place, any of the condition errors will trigger the Contact Closure alarm to be asserted. If one of these jumpers is removed, then the error condition associated with the missing jumper may occur but will not trigger the Contact Closure alarm to be asserted and the Alarm LED will not light. Whenever the contact closure alarm is asserted, the Alarm LED will light and an alarm Contact Closure signal will be sent out.

External Alarm Configure

 

J3A Validity

J3

J3B Confidence

A

B

J3C CRC

C

J3D Parity

D

E

J3E Biphase Code

F

J3F No Lock

 

AU TO EQ

 

MANU SELECT

EXTERNAL ALARM CONFIGURE

AL

J3A VALIDITY

M AN UAL

J3B CONFIDENCE

EQ ADJU ST

 

J3C CRC

ALL OK

J3D PARITY

NO LOCK

J3E BIPHASE CODE

J3F NO LOCK

 

BIPH ASE COD E

J3

 

PARITY

A

CR C

B

CON FIDENC E

C

D

VALID ITY

E

 

F

ALAR M

 

AES-6880

Figure 1-4. AES-6880 Jumper Selection

6

6800/7000 Series - Distribution and Routing Products Installation and Operation Manual

Page 33
Image 33
Nokia 7000 Series, 6800 Series operation manual User Configurable Contact Closure Alarm Indicator, J3C CRC