InstallationChapter 13:
LED Indicators
LED | Indication |
|
|
525 or 625 LED | On indicates that the module is operational |
| and the incoming signal is properly |
| detected. |
|
|
Error LED | Steady On and Black Burst test signal at the |
| analog output indicate the absence of |
| incoming data. |
|
|
Interface Switches
| Switch Setting | Function |
|
|
|
| Standard Select | In the Man position the user can force the |
|
| output standard to the required mode (in |
|
| case of an input signal mismatch the |
|
| module gives the Error LED indication). If |
|
| the user always operates in only one |
|
| standard it is advisable to use the Man |
|
| mode for faster lockup. In Auto mode the |
|
| |
|
| detected line standard. |
|
|
|
| Force | This is to select between 525 and 625 line |
|
| standard modes and active only if Standard |
|
| Select is in Man position. |
|
|
|
| 525 Standard | This is to select between output standards |
|
| NTSC and PALM. Since the incoming |
|
| signal is component digital this selection is |
|
| always made by the user even in the Auto |
|
| mode. |
|
|
|
| Vertical Blanking | In the Pass mode the encoder is |
|
| transparent in the vertical blanking. In the |
|
| Blnk mode any luminance and |
|
| chrominance data is substituted by black. |
|
| (no setup in case of 525 signals.) |
|
|
|
| Vblank Chroma | In the Off position the chrominance |
|
| content is removed from the signal in the |
|
| vertical banking area, otherwise |
|
| transparent. |
|
|
|
|
|
|
6800/7000 Series - Distribution and Routing Products Installation and Operation Manual | 113 |