Chapter 8: |
|
|
|
VPD-6830-DLY Series
Configurations
The fixed delay line can be one of the following amounts: 200, 400, 600, 800, or 1000 ns.
The
To configure a
1.Set the Input Coupling for either AC or DC coupling using jumpers J1 and J2. See Figure
2.Set the Clamping mode on jumper J3 to either Soft, Hard, or No Clamp. See Figure
3.Adjust the gain over a range of
Turn the potentiometer clockwise to increase the gain. Adjust the equalization using the R6
Turn the potentiometer clockwise to obtain more equalization.
Make fine adjustments to the
The
4.Position the delay submodule P2 jumpers horizontally across the jumper sockets (connecting pins 2 and 4, and pins 1 and 3) for Bypass mode.
Position the jumpers vertically for Use mode when the fixed delay line is installed. See Figure
5.Position the delay submodule P3 jumpers either horizontally
(Bypass mode) or vertically (Use mode) across the jumper sockets.
Jumper P3 is a
90 | 6800/7000 Series - Distribution and Routing Products Installation and Operation Manual |