User Interface

 

 

***This configuration decreases board power consumption from 5.4 to 5.0 W and requires that the jumpers be set to Position B. In all other cases, they should be in position A.

Mode Select Switch

Toggle Switch

 

 

 

 

 

Position

Function

Down

Up

 

 

 

 

5

Composite

2 comp+YC: Generates

4 comp: Generates 4

 

 

2 composite and YC

composite analog

 

 

analog outputs.

outputs. Position 4 of

 

 

Position 4 of Mode

the Mode Select switch

 

 

Select switch should be

should be configured

 

 

configured for the

for the Composite

 

 

Composite mode.

mode.***

 

 

 

 

6

Component

RGB: Generates RGB

YUV: Generates YUV

 

 

analog output. Sync is

analog outputs. Sync is

 

 

present on all of the

present on the Y

 

 

outputs. On-board

output. On-board

 

 

potentiometer allows

potentiometer allows

 

 

the adjustment of

the adjustment of the

 

 

overall gain and each

overall gain and each

 

 

channel gain

channel gain

 

 

independently.

independently.

 

 

Position 4 of the Mode

Position 4 of the Mode

 

 

Select switch should be

Select switch should be

 

 

configured for

configured for

 

 

Component output.

Component output.

 

 

 

 

7

V Blanking

Blank: All of the

Pass: All of the

 

 

information in the VBI

information in the VBI

 

 

is blanked: Up to line

is passed without

 

 

20 in 525 line standard,

processing for digital

 

 

up to line 23 in the 625

to analog output.

 

 

line standard.

 

 

 

 

 

8

Setup

Off: The 7.5 IRE

On: The 7.5 IRE

 

 

pedestal is not inserted

pedestal is inserted

 

 

into the analog video in

into the analog video in

 

 

525 line standard.

the 525 line standard.

 

 

 

 

9

Burst

Off: The burst is turned

On: The burst is turned

 

 

off in the 525 or 625

on in the 525 or 625

 

 

line standards.

line standards.

 

 

 

 

A

Chroma

Off: The chrominance

On: The chrominance

 

 

is turned off in the 525

is turned on in the 525

 

 

or 625 line standards.

or 625 line standards.

 

 

 

 