Chapter 2: DNH-6800 DigiNet Hub Module

User Interface

 

 

User Interface

Indicators and Controls

When a signal collision occurs, the DNH-6800 briefly jams all the nodes from transmitting.

The nodes then begin re- transmitting the packets at randomized intervals.

The user interface consists of LEDs that indicate various states or activities, a jumper for disabling Channel 0, and a Reset button. These are described in the table below and shown in Figure 2-5 on page 21.

Indicators

Function

and Controls

 

 

 

Power LED

The green power LED indicates that the DNH-6800 is

 

powered on.

 

 

Channel LEDs

Each channel has a pair of LEDs, one green and one

 

red.

 

• The green LED lights when signal transmission is

 

occurring on that channel.

 

• The red LED briefly lights when a signal collision

 

occurs on that channel.

 

 

Jamming LED

The jamming process occurs in conjunction with the

 

collision detection feature and is indicated by a red

 

LED.

 

 

Channel 0 Disable

Channel 0 is disabled with this jumper.

Jumper

This allows each DNH-6800 module within a single

 

 

frame to act independently.

 

 

Configuration LED

In the event of a configuration failure, this LED

 

remains continuously lit.

 

 

Reset Button

The Reset button is used to reset the DNH-6800

 

module after a configuration failure.

 

 