Nortel Networks 214393-A manual on page, an alarm

Models: 214393-A

1 164
Download 164 pages 33.79 Kb
Page 136
Image 136
Table 50.

136Chapter 8 RMON

 

 

If you want to make field changes, see the field descriptions shown in

 

 

Table 50.

 

Table 50 RMON Insert Alarm dialog box fields

 

 

 

 

 

Field

 

Description

 

 

 

 

 

Variable

 

Name and type of alarm—indicated by the format:

 

 

alarmname.x where x=0 indicates a chassis alarm.

 

 

alarmname. where the user must specify the index. This will be a card number for

 

 

module-related alarms, an STG ID for spanning tree group alarms (the default STG

 

 

is 1, other STG IDs are user-configured), or the Ether Statistics Control Index for

 

 

RMON Stats alarms

 

 

 

alarmname with no dot or index is a port-related alarm and results in display of the

 

 

port selection tool.

 

 

 

 

 

Sample Type

 

Can be either absolute or delta.

 

 

 

For more information about sample types, refer to “Creating alarms” on page 133.

 

 

 

 

Sample Interval

 

Time period (in seconds) over which the data is sampled and compared with the rising

 

 

and falling thresholds.

 

 

 

 

 

Index

 

Uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic

 

 

sample at a particular interval for an object on the device.

 

 

 

 

Threshold Type

 

Rising Value

Falling Value

 

 

 

 

Value

 

When the current sampled value is

When the current sampled value is less than

 

 

greater than or equal to this threshold,

or equal to this threshold, and the value at

 

 

and the value at the last sampling

the last sampling interval was greater than

 

 

interval was less than this threshold,

this threshold, generates a single event.

 

 

generates a single event.

 

 

 

 

 

Event Index

 

Index of the event entry that is used

Index of the event entry that is used when a

 

 

when a rising threshold is crossed. The

falling threshold is crossed. The event entry

 

 

event entry identified by a particular

identified by a particular value of this index

 

 

value of this index is the same as

is the same as identified by the same value

 

 

identified by the same value of the

of the event index object. (Generally, accept

 

 

event index object. (Generally, accept

the default that is already filled in.)

 

 

the default that is already filled in.)

 

 

 

 

 

 

To view the RMON statistics and history for the port for which you have created

 

an alarm:

 

 

1 Select the port on which you have created an alarm.

 

2 From the Device Manager main menu, choose RMON > Control.

 

 

The RMONControl dialog box opens with the History tab displayed

 

 

(Figure 60 on page 126).

 

 

 

 

 