Alarms tab

Chapter 8 RMON 137

3Click the Ether Stats tab to view the statistics (Figure 64 on page 130).

Alarms tab

To view information about alarms:

Click on RMON > Alarms

The RMONAlarms dialog box opens with the Alarms tab (Figure 69) displayed.

Figure 69 RMONAlarms dialog box — Alarms tab

Table 51 describes the fields on the Alarms tab.

Table 51 Describes the fields on the Alarms tab

Field

Description

 

 

Index

Uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic

 

sample at a particular interval for an object on the device

 

 

Interval

The interval in seconds over which data is sampled and compared with the rising and

 

falling thresholds. When setting this variable, note that in the case of deltaValue

 

sampling, you should set the interval short enough so that the sampled variable is very

 

unlikely to increase or decrease by more than 2^31 - 1 during a single sampling

 

interval.

 

 

Variable

The object identifier of the particular variable to be sampled. Only variables that resolve

 

to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks)

 

may be sampled.

 

 

Sample Type

The method of sampling the selected variable and calculating the value to be compared

 

against the thresholds. If the value of this object is absoluteValue(1), the value of the

 

selected variable will be compared directly with the thresholds at the end of the

 

sampling interval. If the value of this object is deltaValue(2), the value of the selected

 

variable at the last sample will be subtracted from the current value, and the difference

 

compared with the thresholds.

 

 

Reference for the BayStack 380-24F Gigabit Switch Management Software

Page 137
Image 137