CS 1000 SIP configuration and UDP location dialing 51
Prompt Response Description
-PFX1 613 Prefix 1
-PFX2 962 Prefix 2
DITI Yes DID to TIE connections allowed.
To connect external DID and internal network TIE trunks
for the customer (which allows an external trunk to be
transferred across an internal network TIE trunk), set
DITI=YES.
LD 17 Configure the Application Module Link (AML).
Prompt Response Description
REQ CHG Change existing data.
TYPE ADAN Action Device And Number
- ADAN NEW ELAN x Action Device And Number
Where x is the ELAN Link number:
x = 32 to 47 (inclusive) for Small Systems
x = 32 to 127 (inclusive) for Large Systems
AML link number within the preceding range implies that
the transport is over TCP/RUDP link.
CTYP ELAN AML over Ethernet card type
LD 17 Configure Value Added Server (VAS).
Prompt Response Description
REQ CHG Change existing data.
TYPE VAS Value Added Server configuration
VAS NEW New Value Added Server data block
- VSID 32-500 VAS Identifier
= 32 to 47 for Small Systems
= 32 to 127 for Large Systems
Nortel recommends that the VAS Identifier match the
ELAN Link number configured in the last step (LD 17 —
Configuring AML).
- ELAN xAssociate Value Added Server ID (VSID) x with Application
Module Link over Ethernet (ELAN) x
Note: The AML ELAN link number must match the number
provisioned in the last step (LD 17 — Configuring AML).
Nortel Communication Server 1000
Communication Server 1000 to MCS 5100 ConvergedDesktop Type 2 Configuration Guide
NN43001-321 01.05 Standard
Release 5.0 15February 2008
Copyright© 2005-2008, Nor tel Networks
.