Page100 of 544 Provisioning
553-3011-100 Standard14.00 January 2002
Model 1
Table24, Digitone receiver (DTR) requirements Model 1, on page117
is based on the following factors:
33 percent intra-office calls, 33 percent incoming calls, and 33 percent
outgoing calls
1.5 percent dial tone delay grade of service
no Digitone DID trunks or incoming Digitone tie trunks
Model 2
Table25, Digitone receiver (DTR) requirements Model 2, on page118
is based on the following factors:
the same traffic pattern as Model 1
Digitone DID trunks or incoming Digitone tie trunks
Poisson 0.1 percent blockage grade of service
Model 3
Table26, Digitone receiver (DTR) requirements Model 3, on page119
is based on the following factors:
15 percent intra-office calls, 28 percent incoming calls, and 56 percent
outgoing calls
1.5 percent dial tone delay grade of service
no Digitone DID trunks or incoming Digitone tie trunks
Model 4
Table27, Digitone receiver (DTR) requirements Model 4, on page120
is based on the following factors:
the same traffic pattern as Model 3
Digitone DID trunks or incoming Digitone tie trunks
Poisson 0.1 percent blockage grade of service