NTAG26XM FR card Page411 of 544
Option11C and 11C Mini Technical Reference Guide
XMFR receiver specifications

Table131 provides the operating requirements for the NTAG26 circuit card.

Table 1 31
XMFR receiver specifications (Part1 of 3)
Coding: Mu-Law
Input sensitivity: must accept: 0 to -25 dBmO
must reject: -35 to dBmO
Frequency sensitivity: must accept: f +/- (1.5 % + 5Hz)
Amplitude Twist: must accept: difference of 6dB between frequencies
Signal Duration: must accept: > 30 ms
must reject: < 10 ms
KP Signal Duration: must accept: > 55 ms
may accept: > 30 ms
must reject: < 10 ms
Signal Interruption Bridge: must ignore: < 10 ms
Time Shift between 2 frequencies:
(Envelop for start/stop)
must accept: < 4 ms