Page108 of 544 Provisioning
553-3011-100 Standard14.00 January 2002
Figure 10
Card slot assignment plan: Option 11C Mini Chassis Expander
t
Provisioning conference/TDS loops

Conference loops

The Conference function is provided by the NTDK20 Small System
Controller (SSC) in Option 11C, and the NTDK97 Mini System Controller
(MSC) in Option 11C Mini.
For the Option 11C, each conference loop supports 16 conferees. By default,
two conference loops are always active, more becomes active when the
expansion cabinets are equipped. Therefore the SSC supports a total of 32
conferees by itself.
Each port on a Fiber Expansion Daughterboard on the Small System
Controller supports an additional conference loop for a total of:
48 conferees when equipped with one Fiber Expansion Link
64 conferees when equipped with two Fiber Expansion Link
Slot 9 - Any IPE card
Slot 8 - Any IPE card
Slot 7 - Any IPE card

Chassis Expander

Slot 10 - Meridian Mail
Mini or any IPE card
SLOT
7
SLOT
8
SLOT
9
SLOT
10
553-9032