Page446 of 544 Cablespecifications and interfaces
553-3011-100 Standard14.00 January 2002
IP connector cables

The Option 11C IP Expansion system requires the following cables:

Environment

The Daughterboards and Receiver cards are subject to the environmental

conditions shown in Table 138.

Table 1 37
IP connector cables
Daughterboards Cable Cable description
NTDK83 and NTDK99
100baseT IP
NTTK34AA /
AO793725
10m RJ45 CAT 5 cable
NTDK8305 /
AO781621
2m STP CAT 5 extension cable
NTTK01 and NTTK02
100baseF IP
AO817052 5 m MT-RJ to ST cable.
A0346816 ST fibre coupler
AO817055 10m MT-RJ to MT-RJ fibre extension
cable
Table 1 38
Environmental conditions
Operating Storage
Ambient temperature 0° C to 50° C
(32° F to 122° F)
-45° C to 70 ° C
(-49° F to 158° F)
Relative Humidity 5% to 95% 0% to 95%