Page402 of 544 NT5K21XMFC/MFE card
553-3011-100 Standard14.00 January 2002
The exact meaning of each MFC signal number (1-15) within each level can 
be programmed separately for each trunk route using MFC. This 
programming can be done by the customer and allows users to suit the needs 
of each MFC-equipped trunk route.
Each MFC-equipped trunk route is associated with a data block that contains 
the MFC signal functions supported for that route. Up to 127 such tables can 
be defined for an Option 11C system.
MFE signalingThe NT5K21 XMFC/MFE card can be programmed for MFE signaling 
which is used mainl y in France. MFE  is much the same as  MFC except it ha s 
its own set of forward and backward signals.
13 1620 Hz + 1980 Hz 900 Hz + 540 Hz
14 1740 Hz + 1980 Hz 780 Hz + 540 Hz
15 1860 Hz + 1980 Hz 660 Hz + 540 Hz
Table 1 23
MFC Frequency values  (Part2 of 2)