SDIports Page231 of 544
Option11C and 11C Mini TechnicalReference Guide
The baud rates available on all three ports are 300, 600, 1200, 2400, 4800, and
19200 baud.
NTAK03 TDS/DTR card
Table74 shows the default settings.
The NTAK03 TDS/DTR card is rep laced by the NTDK20 SSC card in
Option11C, and the NTDK97 MSC in Option 11C Mini. However, it is still
supported and can be retained to gain access to extra ports.

Connecting to the ports

The methods by which external devices may be connected to the TDS/DTR
card are:
Use the NTAK19EC two port SDI cable. The NTAK19EC cable does not
have to be terminated at the cross connect terminal since it is equipped
with connectors.
Use the NE-A25-B cable and terminate it at the cross connect terminal.
Tables75 and 76 give the pinouts for the TDS/DTR card.
Table 7 3
Default port configuration
TTY Number Card Port Use Configuration
0 0 0 MTC/SCH/BUG 1200/8/1/NONE
1 0 1 MTC/SCH/BUG 1200/8/1/NONE
2 0 2 CTY 1200/8/1/NONE
Table 7 4
Default port configuration
TTY Number Card Port Use Configuration
0 0 0 MTC/SCH/BUG 1200/8/1/NONE
1 0 1 MTC/SCH/BUG 1200/8/1/NONE
2 0 2 CTY 1200/8/1/NONE