NT5K21XMFC/MFE card Page403 of 544
Option11C and 11C Mini TechnicalReference Guide
Table124 on page 403lists the forward and backward frequencies for MFE.
The one backward signal for MFE is referred to as the control frequency.
Sender and receiver mode
The XMFC/MFE circuit card provides the interface between the Option 11C
CPU and the trunk circuit which uses MFC or MFE signaling.
The XMFC/MFE circuit card transmits and receives forward and backward
signals simultaneously on two channels. Each channel is programmed like a
peripheral circuit card unit, with its own sending and receiving timeslots in
the Meridian network.
Table 1 24
MFE Frequency values
Digit Forward direction
OG-Tx, IC-Rx Backward direction
1700 Hz + 900 Hz 1900 Hz
(Control Frequency)
2700 Hz + 1100 Hz
3900 Hz + 1100 Hz
4700 Hz + 1300 Hz
5900 Hz + 1300 Hz
61100 Hz + 1300 Hz
7700 Hz + 1500 Hz
8900 Hz + 1500 Hz
91100 Hz + 1500 Hz
10 1300 Hz + 1500 Hz