47
TOPS VSN Log and alarm messages
8. Common TOPS VSN logmessages - 0020
0001/0000
Message:
[PRU_name] could not insert Control Link PRU in data structure. It
is full. Maximum number of control links supported = [max_number]
Description:
The maximum number of controls links the system can support
has been reached. The maintenance notice PRU is still working but will only
send notices to the first [max_number] control links up.
Action:
No action
0001/0001
Message:
[PRU_name] could not insert a maintenance notice in data
structure. Structure is full. Maximum number of notices supported =
[max_number].
Description:
The maximum number of maintenance notices the system can
support has been reached.
Action:
The user must delete some notices.
0001/0002
Message:
[PRU_name] could not insert a DMS-link tuple in data structure.
Structure is full. Maximum number of links supported is [max_number].
Description:
The maximum number of DMS-links the system can support
has been reached.
Action:
The user must delete some links.