15.Locality database log messages - 944E

0000/0000 Message: The Locality Database has just become operational. Locality queries can now be processed. Any pending minor alarms against the Locality Database have been cleared.

Description: This is an information message only.

Action: None.

0000/0001 Message: The LDB has detected a serious problem which prevents it from initializing.

"Diagnostic String 1"

"Diagnostic String 2"

Description: A serious error was encountered by the LDB PRU during initialization. The LDB PRU will be automatically rebooted by the system. The first diagnostic string describes the nature of the problem, and the second diagnostic string gives more information on the problem.

Action: No action is required unless the condition persists.

0000/0002 Message: The LDB has detected a serious problem in initialization in either a query handler or the MMI which it cannot recover from. Initialization will continue. A minor alarm will be generated, which can be cleared by rebooting the LDB PRU or from the Alarm Query MMI.

"Diagnostic String 1"

"Diagnostic String 2"

Description: The first diagnostic string describes the nature of the problem. This string will indicate whether the log concerns a query handler or the MMI. If it concerns a query handler, it will show the current number of query handlers. The second diagnostic string gives more information about the problem.

Action: No explicit action is required immediately, as the LDB can continue with initialization, but with diminished capacity, as indicated in the log message. If the query processing capacity is too low, or if the MMI processing has failed, the LDB PRU should be rebooted.

0000/0003 Message: The Locality DataBase has detected a problem in initialization of Custom Branding information. Initialization will continue.

"Diagnostic String 1"

"Diagnostic String 2"

TOPS VSN Log and alarm messages