52 Alarm Subsystem (8722)

 

Action: The system administrator must check the status of the APTIO port

 

according to NTP 450-1011-301. If the fault has not been detected at the

 

port, the operation of the LIU must be checked. It must also be determined

 

if the cabling from the DNC to the LIU is intact.

0005/0002

Message: The alarm subsystem has recovered communication with the

 

APTIO port. APTIO port <string>.

 

Explanation: The alarm subsystem was able to reconnect with the APTIO

 

port and is now functioning properly. The link between the alarm subsystem

 

and the alarm box has been restored and is functioning normally.

 

Action: No action required by the user.

0020/0000

Message: Unable to access disk "LOCAL".

 

Explanation: This log indicates that a communication error has occurred to

 

the local system disk. Call processing will not be interrupted. Locality calls

 

will be handled according to parameter LOC_DEFAULT_PROMPT in the

 

user interaction table.

 

Action: If the problem persists, retain all of the information regarding the

 

problem and contact your NT representative.

0020/0001

Message: I/O Error <I/O-error-number> saving log to disk.

 

The new alarm subsystem history file was created successfully.

 

Explanation: The alarm subsystem has recovered from the error situation by

 

creating a new history file and starting fresh. The original history file was

 

renamed from ALARMHIST to ALARMHIST.YY_MM_DD.

 

Action: No action required by the user.

0020/0002

Message: Unrecoverable I/O Error <I/O-error-number> saving log to disk.

 

Action may be required by the system administrator.

 

Explanation: The alarm subsystem could not recover from the error

 

situation by creating a new history file and starting fresh.

 

Action: A system administrator with superuser authority must remove the

 

current alarm history file :LOCAL:PRU:LOGS:HISTORY:ALARMHIST and

 

then reload the alarm subsystem PRU.

0020/0003

Message: The alarm subsystem disk task was unable to find its initialization

 

file: :LOCAL:PRU:LOGS:AL:ALINIT.TEXT. Default values have been

 

supplied.

 

Explanation: The alarm system's initialization file is probably missing from

 

the system. The alarm subsystem initializes itself using available default

 

values.

 

Action: A system administrator with superuser authority must check the load

 

tape for the presence of the initialization file and replace this file if

 

necessary.

0020/0004

Message: The Current Alarm Service history file is larger than that specified

 

in the initialization file ':LOCAL:PRU:LOGS:AL:ALINIT'. A new alarm

subsystem history file was created successfully.

Explanation: The alarm subsystem has created a new history file and is starting fresh. The original history file was renamed from ALARMHIST to ALARMHIST.YY_MM_DD.

Action: No action required by the user.

TOPS VSN Log and alarm messages

Page 58
Image 58
Nortel Networks VSN04 manual Alarm Subsystem