51

10. Alarm Subsystem - 8722

0001/0001

Message: Alarm Interface Unit has RECEIVED an external alarm.

 

External ALIU input is: <string>.

 

Explanation: The ALIU has sensed remote activation of an alarm condition.

 

The string stating the error is one of the following:

 

FAN 1 FAILURE

 

POWER CONVERTER 1 FAILURE

 

POWER CONVERTER 2 FAILURE

 

FUSE FAILURE

 

FAN 2 FAILURE

 

POWER CONVERTER 3 FAILURE

 

POWER CONVERTER 4 FAILURE

 

USER 1 INPUT

 

USER 2 INPUT

 

USER 3 INPUT

 

Action: The system should be serviced according to the troubleshooting

 

procedures in NTP 450-1011-501. System troubleshooting should only be

 

performed by qualified service personnel (that is, a system administrator or

 

maintenance technician).

0001/0002

Message: Alarm Interface Unit has RECOVERED an external alarm.

 

External ALIU input is: <string>.

 

Explanation: The ALIU has sensed the clearing of the externally generated

 

alarm. The string stating the error is one of the following:

 

FAN 1

 

POWER CONVERTER 1

 

POWER CONVERTER 2

 

FUSE

 

FAN 2

 

POWER CONVERTER 3

 

POWER CONVERTER 4

 

USER 1 INPUT

 

USER 2 INPUT

 

USER 3 INPUT

 

Action: No action required by the user.

0005/0001

Message: The alarm subsystem has lost communication with the APTIO

 

port. Please check the status of the APTIO port <port-name>.

 

Explanation: The link between the alarm subsystem and the "alarm box" has

 

been disconnected. The alarm box is a separate visual indicator of alarms.

TOPS VSN Log and alarm messages

Page 57
Image 57
Nortel Networks VSN04 manual Alarm Subsystem, User 3 Input