24Common TOPS VSN log messages (0202)

Description: The PRU encountered an error during an IO operation on the file or directory. The operation was not performed. It is the responsibility of the PRU performing the operation to recover from the error and to retry the operation. If it is unable to do so, then it can declare itself faulty.

Action: If the PRU is in the working state, no action is required. If the PRU is in the faulty state, then reboot the PRU. If the problem persists, then reboot the server which handles the IO operation. If neither reboot operations are successful, then reboot the whole system. Document the problem, record all action taken, and then contact NT.

0003/0067 Message: [PRU_name] received an IO error (Cannot_Create) on path [file/directory_path name]. The "server" error was the result of not being able to create the specified file (or path).

Description: The PRU encountered an error during an IO operation on the file or directory. The operation was not performed. It is the responsibility of the PRU performing the operation to recover from the error and to retry the operation. If it is unable to do so, then it can declare itself faulty.

Action: If the PRU is in the working state, no action is required. If the PRU is in the faulty state, then reboot the PRU. If the problem persists, then reboot the server which handles the IO operation. If neither reboot operations are successful, then reboot the whole system. Document the problem, record all action taken, and then contact NT.

0003/0068 Message: [PRU_name] received an IO error (Duplicate_Name) on path [file/directory_path name]. The "server" error was the result of attempting to create a file (or directory) when the entity already exits.

Description: The PRU encountered an error during an IO operation on the file or directory. The operation was not performed. It is the responsibility of the PRU performing the operation to recover from the error and to retry the operation. If it is unable to do so, then it can declare itself faulty.

Action: If the PRU is in the working state, no action is required. If the PRU is in the faulty state, then reboot the PRU. If the problem persists, then reboot the server which handles the IO operation. If neither reboot operations are successful, then reboot the whole system. Document the problem, record all action taken, and then contact NT.

0003/0069 Message: [PRU_name] received an IO error (Bad_Address) on path [file/directory_path name]. The "server" error was the result of specifying a bad address.

Description: The PRU encountered an error during an IO operation on the file or directory. The operation was not performed. It is the responsibility of the PRU performing the operation to recover from the error and to retry the operation. If it is unable to do so, then it can declare itself faulty.

Action: If the PRU is in the working state, no action is required. If the PRU is in the faulty state, then reboot the PRU. If the problem persists, then reboot the server which handles the IO operation. If neither reboot operations are successful, then reboot the whole system. Document the problem, record all action taken, and then contact NT.

TOPS VSN Log and alarm messages

Page 30
Image 30
Nortel Networks VSN04 manual Common Tops VSN log messages