Olivetti 16W, 20W B. Misfeed in the fusing area, Push gently on both ends of the front cover

Models: 20W 16W

1 74
Download 74 pages 2.13 Kb
Page 54
Image 54
B. Misfeed in the fusing area

TROUBLESHOOTING

B. Misfeed in the fusing area

1 Push gently on both ends of the front cover.

4 Lift the fusing unit release levers, to return them to their operating positions.

2 Turn the roller rotating knob in the direction of the arrow.

5 Close the front cover and side cover.

Roller rotating knob1 Push gently on both ends of the front cover.2 Turn the roller rotating knob in the direction of the arrow.5 Close the front cover and side cover.

The misfeed indicator (3 Carefully remove the misfed paper.) will go out.

3 Carefully remove the misfed paper.

 

When closing the front cover, gently hold

Lower the fusing unit release levers to

Note

 

both ends.

allow easier removal.

 

 

When closing the side cover, press on the

Fusing unit

Be careful not to tear the

 

 

handle.

release lever

misfed paper during

 

If the misfeed indicator ( ) does not stop

 

removal.

 

 

blinking, check for torn pieces of paper in

 

 

 

 

the machine.

Warning

The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or injury.

Caution

Do not touch the photoconductive drum (green portion) when removing the misfed paper. Doing so may damage the drum and cause smudges on copies.

Be careful about unfixed toner on the misfed paper not to soil your hands or clothes.

50

Page 54
Image 54
Olivetti 16W B. Misfeed in the fusing area, Push gently on both ends of the front cover, Carefully remove the misfed paper