2.1.5.4 Dip Switches

2.1.5.4 Dip Switches

To change the DIP switches, follow the instructions below:

1. The unit should be removed from the panel and opened.

Refer to Section 2.1.4.3 for assembly and disassembly instructions.

2. Locate the 4 and 8 position DIP switches, on the top board. The Meter is shipped with all DIP switches in "OFF" position

To set the Wireless and Ethernet settings to Factory Default, Refer to Section 7.

8 Position S1 14 PositionFigure 2.11 Location of DIP SwitchesManual backgroundManual backgroundManual backgroundManual background

8

OFF

1

 

8

ON

OFF

 

ON

ON

8 Position

DIP Switch on

Wireless Board

1 To change the Wireless settings to Factory Default

2-8 N/A

4 3 2 OFF Manual backgroundManual background1

 

 

4

3 2

1

 

 

 

 

 

4 Position

 

 

OFF

 

 

 

 

 

DIP Switch on

ON

 

 

 

Ethernet Board

 

 

1

 

 

 

N/A

 

 

 

2

To change the Ethernet settings to

3

Factory Default

 

 

 

To enable/disable DHCP

 

4

N/A

 

 

 

Figure 2.11 Location of DIP Switches