Omega WI8XX-U manual Analog Output Retransmission, Output High, Setup

Models: WI8XX-U

1 92
Download 92 pages 14.59 Kb
Page 49
Image 49
4.3.7.4 Analog Output Retransmission

4.3.7.4 Analog Output Retransmission

This menu will appear only if you have the Analog Output Option installed in your Meter.

SETUP

Address http://192.168.1.200

SETUP

Analog Output Retransmission

Retransmission

Voltage/Current

Input Low

Output Low

Input High

Output High

Enabled

Voltage

0

0.00 Min. 0V

1000

10.00 Max. 10V

Update

Cancel

Main Menu

Figure 4.18 Analog Output Retransmission Retransmission: When enabled, the input data will be scaled based on Input Low and Input High and will be outputted. If the input reaches high value the output will be 10V or 20mA. If the input reaches low value, the output will be 0V or 0mA.

Voltage/Current: Select the output to be Voltage (0-10V) or Current (0-20mA).

Input Low: The minimum input value scaled for Output Low.

Output Low: Output Voltage or Current represented by Input Low.

Input High: The minimum input value scaled for Output High.

Output High: Output Voltage or Current represented by Input High.

43

Page 49
Image 49
Omega WI8XX-U Analog Output Retransmission, Retransmission Voltage/Current Input Low Output Low Input High, Output High