4.3.6 Controller Setup (continued)

Below are the definitions of terms used in the Controller Setup page.

A) Setup:

Clicking on the options shown, allows user to modify the different parameters shown under this menu (see Section 4.3.7. Setup Page for more details)

B) Monitor:

Scrolling: If checked, the Meter will display data from all the End Devices. Otherwise, it only displays data from the End Device specified on Device ID. End Device ID: Address/ID of the End Device that will be display on the Meter.

C) Transmission Power:

Channel 12: The Meter communicates in a fixed channel. Operation channel #12 defined in IEEE 802.15.4 for the sensor network.

Transmission Power: This determines the signal power transmitted by the Meter. The options are 10 dBm and 20 dBm.

Please refer to local regulations for the allowed maximum transmission power.

For additional details, please refer to Appendix F

D) Miscellaneous:

PID 13106 (version): The Personal Network ID is fixed to 13106. In parenthesis is the firmware version of the radio module. The firmware version is also shown on a label attached to the Meter (see Figure 3.1).

iSeries Version: The firmware version of the Meter. The firmware version is also shown on a label attached to the Meter (see Figure 3.1)