4.3.2 Get Readings from the End Device

4.3.2 Get Readings from the End Device

Once you see the End Device’s LED blinking periodically, it means it is sending data which will appear on the "Readings" page. To view the data in a chart format, you can use the "Chart" page.

Click on Readings from the Home Page, the following page will appear, showing updates of the Process and Ambient Temperature.

wiSeries

 

 

 

 

 

 

 

 

 

 

Lab 100

 

Process

F

 

 

Ambient

F

 

 

73

 

 

 

70

 

ID: 1

Sequence: 10

Stre

ngth: 100%

Success: 100%

Battery:

3.78V

Update: 120sec

Running

Lab 200

 

77

 

F

 

 

68

F

 

ID: 2

Sequence: 24

Strength: 94%

Success:

100%

Battery:

3.67V

Update: 120sec

Running

Lab 700

 

78

 

F

 

 

75

F

 

ID: 7

Sequence: 28

Strength: 21%

Success:

100%

Battery:

3.67V

Update: 120sec

Running

Data Logging: INACTIVE

Refresh 5 seconds

Main Menu

Figure 4.7 Readings

While accessing the "Readings" page, If a blank screen appears without any "java application running" or image of a "Java logo", please verify you have the latest Java Runtime Environment installed and configured according to the Section 4.3.3.1. If you do not have Java Runtime Environment, you may download it from our website or contact the Customer Service Department nearest you.

The "Readings" fields are defined as follows:

Title: Meter’s name, assigned in Network Setup Menu.

Name: End Device’s name, assigned in End Device Setup Menu.

Reading Values: The order from left to right is Process Temperature, then Ambient. First Reading: Process - process temperature reading with temperature unit. Second Reading: Ambient - built-in sensor temperature reading with temperature unit.

Reading "Open" indicates that no sensing device is detected.