Installing Oracle Connect on an IBM OS/390 or z/OS Series Platform
6-4 Oracle Application Server Adapter for IMS/TM User’s Guide
Preinstallation InstructionsBefore starting the installation, ensure that the following information is available:
■The output class for the installation output if you do not want to use the default
value, which is A.
■The unit where SMS resides. If you use SMS to manage all datasets, then you
cannot provide unit and volume information.
Before starting the installation, ensure that you have the following permissions:
■Permission to define an APF-authorized library.
■Permission to write to an active proclib, such as user.proclib.
■Permission to update the security manager, such as RACF.
-Unit 3390 SMS only: unit where SMS resides.
-Output class A -
-JCL job card -An optional card (up to 6 lines) to replace
the prefix job (entered as it will appear in
the job)
-ISPF load library name ISP.SISPLOAD -
Table 6–6 Required Permissions
Permission
Permission to define an APF-authorized library
Permission to write to an active proclib, such as user.proclib
Permission to update the security manager, such as RACF
Optionally, permission to specify an output class for Oracle Connect output
Table 6–7 Installation Checklist
Step Comment/Outputs
tso profile prefix Ensures that the user name is not used as part of
the dataset name allocated in the next steps
Allocate dataset: {HLQ}.TRANSMIT.KIT 130 tracks (3390), format=FB, record length=80,
block size=3120
Allocate dataset: {HLQ}.TRANSMIT.LOAD 420 tracks (3390), format=FB, record length=80,
block size=3120
Copy files to OS/390 (or z/OS) FTP using binary mode
RECEIVE INDSNAME('{HLQ}.TRANSMIT.KIT') -
da('{HLQ}.TRANSMIT.LIB') UNIT(unit) VOLUME(volume) -
EX {HLQ}.TRANSMIT.LIB(PREPARE) Successful MAXCC is 0, 4 or 8
BUILDKIT.SRC and BUILDKIT.LOAD created
EX {HLQ}.BUILDKIT.SRC(NAVINST) Successful MAXCC is 0 or 4
Table 6–5 (Cont.) Preinstallation Information
Topic Required Information Default Comment