Installing Oracle Connect on an IBM OS/390 or z/OS Series Platform
Installing and Configuring OracleAS Adapter for IMS/TM 6-5
Oracle Connect for the IBM OS/390 or z/OS platform is contained in the following
datasets:
OCL1012.TRANSMIT.KIT
OCL1012.TRANSMIT.LOAD
These datasets are provided on a CD-ROM in the following directory:
Oracle_Connect\IMSTM_Legacy_Adapter
Installing the Kit
Perform the following steps on the Mainframe:
1. Run the following command:
tso profile noprefix
The user name will not be used as part of the dataset name. On some systems this
is the default.
2. Allocate datasets with the following space for each of these files:
OCL1012.TRANSMIT.KIT = 130 tracks (3380 and 3390 disks)
OCL1012.TRANSMIT.LOAD = 420 tracks (3380 and 3390 disks)
For each dataset: RECFM=FB and LRECL=80. The block size is 3120.
3. Using FTP, copy OCL1012.TRANSMIT.KIT and OCL1012.TRANSMIT.LOAD in
the binary mode from the installation CD to the mainframe. You can replace the
OCL1012 high-level qualifier to any qualifier you want.
Installation Instructions
Perform the following steps to install Oracle Connect:
1. Run the following command at the TSO prompt:
RECEIVE INDSNAME('nnn.TRANSMIT.KIT')
Where nnn represents the high-level qualifier you want to assign for the Oracle
Connect installation. Assign the high-level qualifier you specified in step 7 of the
preinstallation procedure. The default value is OCL1012.
2. Enter the following when prompted for the restore parameters:
Note: Optionally, ensure that you have permission to specify an
output class for Oracle Connect output. Assigning a device that is
set on HOLD prevents the loss of log information when Oracle
Connect started tasks finish.
Note: You can use more than one high-level qualifier (such as
ACME.DEV.OCL1012) with the following conditions:
The total length must be less than or equal to twenty characters.
The words transmit and buildkit cannot be used as high-level
qualifiers.