Connection of the DC OUT connector and External

REC start/stop switch

It is possible to draw 1.5 A current from the DC OUT connector of the unit.

Recording start/stop can be controlled by connecting an external switch to this connector.

Since a tally lamp can be used by connecting an LED to this connector, it is useful for shooting video when fixing the camera on a crane.

Note

Make sure the total of current output from DC OUT, REMOTE, VF, and LENS connector do not exceed 2.5 A.

Preparation

DC OUT connector

Connector at the cable side

41 HR10A-7P-4P(73) (Hirose Denki)

3 2

LED

Resistance

Max. 50 mA

Recording start/stop

1:GND

2:TALLY OUT

Open collector output on the unit side.

TALLY ON:

Low impedance

TALLY OFF:

High impedance

3:Recording start/stop switch

This is connected in parallel to the REC START button on the unit or the VTR button on the lens.

4:+12 V

Preparation: Connection of the DC OUT connector and External REC start/stop switch 125