REC FUNCTION

 

Items/

Adjustable

Remarks

Data Saved

Range

 

INTERVAL REC

ON

Sets INTERVAL REC function.

MODE

ONE SHOT

ON: Uses internal memory to perform

 

 

 

 

 

OFF

interval recording.

 

 

 

 

 

 

 

 

 

 

 

 

ONE SHOT:

 

 

 

 

 

 

Performs “one-shot” recording

 

 

 

 

 

 

for the duration specified under

 

 

 

 

 

 

REC TIME, and then stops.

 

 

 

 

 

 

OFF: INTERVAL REC is not

 

 

 

 

 

 

performed.

 

 

 

 

 

 

Note

 

 

 

 

 

 

This item cannot be changed when “ON”

 

 

 

 

 

 

is selected in LOOP REC MODE.

C

U

F

 

 

INTERVAL REC

ON

Selects whether INTERVAL REC MODE

HOLD

OFF

settings are retained or not when the

 

 

 

 

 

 

power is turned off once.

 

 

 

 

 

 

ON: Retain

 

 

 

 

 

 

OFF: Do not retain. The INTERVAL

 

 

 

 

 

 

REC MODE is “OFF” whenever

 

 

 

 

 

 

the power is turned on again.

C

U

F

 

 

REC TIME*

00s01f

Set recording time for INTERVAL REC

 

 

 

 

 

:

(1 cut).

 

 

 

 

 

59s29f

Note

 

 

 

 

 

 

 

 

 

 

 

 

However the settings can be made

 

 

 

 

 

 

frame by frame, and the numbers of the

 

 

 

 

 

 

cut-off unit frames for the shortest time

 

 

 

 

 

 

period and the set time on the actual

 

 

 

 

 

 

operation may vary with the recording

 

 

 

 

 

 

method. For details, refer to [Interval

 

 

 

 

 

 

Recording] (page 44).

C

U

F

 

 

PAUSE TIME*

00h00m00s01f

Specify pause time for INTERVAL REC.

 

 

 

 

 

:

Note

 

 

 

 

 

00h04m59s23f

However the settings can be made

 

 

 

 

 

:

 

 

 

 

 

frame by frame, and the numbers of the

 

 

 

 

 

23h59m59s29f

 

 

 

 

 

cut-off unit frames for the shortest time

 

 

 

 

 

 

 

 

 

 

 

 

period and the set time on the actual

 

 

 

 

 

 

operation may vary with the recording

 

 

 

 

 

 

method. For details, refer to [Interval

 

 

 

 

 

 

Recording] (page 44).

C

U

F

 

 

TAKE TOTAL

NONE

Specify the time needed for INTERVAL

TIME

:

REC.

 

 

 

 

 

5day

Select from “NONE” (continue until

 

 

 

 

 

 

 

 

 

 

 

 

operation is manually stopped) to

 

 

 

 

 

 

5 days.

C

U

F

 

 

TOTAL REC

NONE

Display total recorded time for

TIME*

00m00s01f

INTERVAL REC. The setting cannot be

 

 

 

 

 

:

changed using this option. Displays the

 

 

 

 

 

99m59s29f

 

 

 

 

 

recording time (recording time needed

 

 

 

 

 

OVER100min

 

 

 

 

 

for the P2 card) calculated using REC

 

 

 

 

 

 

 

 

 

 

 

 

TIME, PAUSE TIME, and TAKE TOTAL

 

 

 

 

 

 

TIME.

 

 

 

 

 

 

Note

 

 

 

 

 

 

A value based on actual processing is

 

 

 

 

 

 

displayed.

 

 

AUDIO REC

ON

Select whether or not sound will be

 

 

 

 

 

OFF

recorded during INTERVAL REC.

C

U

F

 

 

START DELAY

0SEC

Set the delay after pressing REC START

 

 

 

 

 

:

to start recording in INTERVAL REC.

 

 

 

 

 

10SEC

 

C

U

F

 

 

*This variable range is the numerical values for 59.94 Hz. For

50 Hz, the frame rate is up to 24f. The frame rate is up to 23f in 24PN (Native) mode.

 

Items/

Adjustable

 

Remarks

Data Saved

Range

 

 

 

PRE REC MODE

ON

Select whether or not to enable PRE

 

 

 

 

 

OFF

RECORDING.

 

 

 

 

 

 

ON:

PRE RECORDING enabled.

 

 

 

 

 

 

OFF:

PRE RECORDING disabled.

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

Specify the PRE RECORDING time by

 

 

 

 

 

 

using the menu option PRE REC TIME.

C

U

F

 

 

 

PRE REC TIME

1SEC

Set PRE RECORDING.

 

 

 

 

 

:

1-8SEC:

 

 

 

 

 

8SEC

 

Set the length of time that can be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

retrospectively recorded before

 

 

 

 

 

 

 

the REC START button is

 

 

 

 

 

 

 

pressed.

C

U

F

 

 

 

LOOP REC

ON

Select whether or not to enable LOOP

MODE

OFF

REC.

 

 

 

 

 

 

 

This setting can be used with PRE

 

 

 

 

 

 

RECORDING features.

 

 

 

 

 

 

ON:

Enable LOOP REC.

 

 

 

 

 

 

OFF:

Disable LOOP REC.

 

 

 

 

 

 

Notes

 

 

 

 

 

 

After the power is turned off, this item

 

 

 

 

 

 

will default to “OFF” the next time the

 

 

 

 

 

 

power is turned on.

 

 

 

 

 

 

This item cannot be changed when

 

 

 

 

 

 

“ON” or “ONE SHOT” is selected in

 

 

 

 

 

 

INTERVAL REC MODE.

F

 

 

 

REC START

ALL

Select operating modes that allow

 

 

 

 

 

NORMAL

recording to start.

 

 

 

 

 

 

ALL: Allow recording to start during

 

 

 

 

 

 

 

stop, recording pause, and

 

 

 

 

 

 

 

playback.

 

 

 

 

 

 

NORMAL:

 

 

 

 

 

 

 

Allow recording to start during

 

 

 

 

 

 

Note

stop and recording pause.

 

 

 

 

 

 

 

 

 

 

 

 

 

Even if this is set to “ALL”, the operation

 

 

 

 

 

 

is “NORMAL”, when “ON” or “ONE

 

 

 

 

 

 

SHOT” is selected in INTERVAL REC

 

 

 

 

 

 

MODE.

 

C

U

F

 

 

 

P.ON REC SLOT

HOLD

Select the recording order of the slot

SEL

SLOT1

when the power is turned on.

 

 

 

 

 

 

HOLD: The recording order starts with

 

 

 

 

 

 

 

the card previously selected

 

 

 

 

 

 

 

when the power was turned off.

 

 

 

 

 

 

SLOT1: The recording order starts with

 

 

 

 

 

 

 

the card that is inserted in slot 1

 

 

 

 

 

 

 

when the power is turned on.

C

U

F

 

 

 

Note

Displayed REC TIME, PAUSE TIME and TOTAL REC TIME are translated into either drop-frame or non-drop-frame according to the mode of operation.

TAKE TOTAL TIME is actual time. Therefore, TOTAL REC TIME may incorporate fractions, depending on the settings.

Example of drop-frame

REC TIME

02s00f

PAUSE TIME

02s00f

TAKE TOTAL TIME

40min

TOTAL REC TIME

19m59s06f

172 Menu: Menu Description Tables