6.Recording Error
Display window | “00:00:00:11” appears in the time code | |
display field. Even after recording is | ||
indication | stopped, this display continues to blink | |
| until the next operation is performed. | |
|
| |
WARNING lamp | Blinks 4 times per second while recording | |
continues. | ||
| ||
|
| |
Tally lamp | Blinks 4 times per second while recording | |
continues. | ||
| ||
|
| |
Viewfinder | The “REC WARNING” indicator lights up. | |
|
| |
Warning tone | Beeps 4 times per second while recording | |
continues. | ||
| ||
|
| |
| This indicates a failure either in the P2 | |
| card recording or the recording circuit. | |
Warning description | This is displayed when attempting to | |
record clips where the total quantity | ||
| ||
| exceeds the upper limit (1000 pieces) for | |
| a single P2 card. | |
|
| |
Recording/playback | The recording may stop or continue. | |
operation | ||
| ||
| Confirm the recording/playback operation | |
Countermeasures | after turning off the power supply once | |
and then turning it on again. | ||
| If the recording cannot be performed | |
| normally, change the P2 card. | |
|
|
7.Low Wireless Signal Reception
Display window | No display. | |
indication | ||
| ||
|
| |
WARNING lamp | Blinks 4 times per second (during pause | |
and recording). | ||
| ||
|
| |
Tally lamp | Blinks 4 times per second while recording | |
continues. | ||
| ||
|
| |
Viewfinder | The | |
while recording continues. | ||
| ||
|
| |
Warning tone | Beeps 4 times per second while recording | |
continues. | ||
| ||
|
| |
Warning description | This error indicates poor wireless audio | |
reception conditions. | ||
| ||
|
| |
Recording/playback | Continues to operate without receiving | |
operation | the wireless microphone signal. | |
Countermeasures | Check the microphone power supply and | |
the reception status of the wireless | ||
| receiver. | |
|
|
8.Battery Nearly Empty
Display window | One of the bars in the battery remaining | |
indication | indicator starts blinking. | |
|
| |
WARNING lamp | Blinks once per second. | |
|
| |
Tally lamp | Blinks once per second. | |
|
| |
Viewfinder | The “BATT” LED blinks. | |
|
| |
Warning tone | Beeps 4 times per second. | |
|
| |
Warning description | The battery is about to run out. | |
|
| |
Recording/playback | Continues to operate. | |
operation | ||
| ||
Countermeasures | Replace the battery as required. | |
|
|
9.P2 Card Nearly Full
Display window | One of the bars for remaining MEDIA | |
indication | capacity starts blinking. | |
|
| |
WARNING lamp | Blinks once per second while recording | |
continues. | ||
| ||
|
| |
Tally lamp | Blinks once per second while recording | |
continues. | ||
| ||
|
| |
Viewfinder | The P2 card remaining capacity indicator | |
blinks. | ||
| ||
|
| |
Warning tone | Beeps once per second while recording | |
continues. | ||
| ||
|
| |
Warning description | The total remaining capacity of all the P2 | |
cards is 2 minutes or less. | ||
| ||
|
| |
Recording/playback | Continues to operate. | |
operation | ||
| ||
Countermeasures | Replace the cards. If there is an empty | |
card slot, insert a new card. | ||
| ||
|
|
10. P2 Card Error |
| Maintenance | |
| If the error occurs during recording, | ||
|
| ||
| “00:00:00:11” appears in the time code |
| |
Display window | display field. The indication continues to |
| |
flash after recording is stopped and until |
| ||
indication |
| ||
the next operation is performed. There is |
| ||
|
| ||
| no indication if the error occurs during | and | |
| playback. | ||
|
| ||
|
|
| |
| If the error occurs during recording, the | Inspections | |
WARNING lamp | lamp flashes 4 times per second for a | ||
| |||
period of about 3 seconds after recording |
| ||
| stops. The lamp does not light if the error |
| |
| occurs during playback. |
| |
|
|
| |
| If the error occurs during recording, the |
| |
Tally lamp | lamp flashes 4 times per second for a |
| |
period of about 3 seconds after recording |
| ||
| stops. The lamp does not light if the error |
| |
| occurs during playback. |
| |
|
|
| |
| A flashing “CARD ERR ” appears. In |
| |
Viewfinder | the actual indication the is replaced by |
| |
the slot number of the P2 card that |
| ||
|
| ||
| triggered the error. |
| |
|
|
| |
| If the error occurs during recording, the |
| |
Warning tone | tone sounds 4 times per second for a |
| |
period of about 3 seconds after recording |
| ||
| stops. The tone does not sound if the |
| |
| error occurs during playback. |
| |
|
|
| |
Warning description | An error has occurred while recording |
| |
data to or playing data from a P2 card. |
| ||
|
| ||
|
|
| |
Recording/playback | Stop recording or playback. |
| |
operation |
| ||
|
| ||
Countermeasures | Replace the affected P2 card. |
| |
|
|
|
Maintenance and Inspections: Warning System 161