Items/

Adjustable

 

Remarks

Data Saved

Range

 

 

 

VITC UB MODE

USER/EXT

Select the user bits mode for VAUX TC

 

 

 

 

 

TIME

(VITC).

 

 

 

 

 

 

DATE

USER/EXT:

 

 

 

 

 

TCG

 

 

 

 

 

 

If UB MODE is set to “EXT”, the

 

 

 

 

 

FRM RATE

 

 

 

 

 

 

 

EXT value is recorded. If not,

 

 

 

 

 

REGEN

 

 

 

 

 

 

 

 

USER value set by UB is

 

 

 

 

 

 

TIME:

recorded.

 

 

 

 

 

 

Select local time (hours,

 

 

 

 

 

 

 

minutes, seconds).

 

 

 

 

 

 

DATE: Select local date and time (2 last

 

 

 

 

 

 

TCG:

digits of year, month, date, time).

 

 

 

 

 

 

TCG value enters UB.

 

 

 

 

 

 

FRM RATE:

 

 

 

 

 

 

 

Select camera shooting

 

 

 

 

 

 

 

information (frame rate, etc.).

 

 

 

 

 

 

 

For more information, see

 

 

 

 

 

 

 

[Frame rate information

 

 

 

 

 

 

 

recorded in user bits] (page 66).

 

 

 

 

 

 

REGEN: Read out value stored in card

 

 

 

 

 

 

Note

and record value continuously.

 

 

 

 

 

 

 

 

 

 

 

 

 

When the unit operates in 24P, 24PA,

 

 

 

 

 

 

and Native mode, the “FRM RATE” is

 

 

 

 

 

 

fixed.

 

C

U

F

 

 

 

TCG SET HOLD

ON

On/off switching for the feature that

 

 

 

 

 

OFF

always starts recording (when the power

 

 

 

 

 

 

is turned on again) the TCG value that

 

 

 

 

 

 

was set before the power is turned off.

C

U

F

 

 

 

FIRST REC TC

PRESET

For selecting whether the time code is

 

 

 

 

 

REGEN

regenerated to the value on the P2 card

 

 

 

 

 

 

when first recording after switching on

 

 

 

 

 

 

the power, inserting the P2 card or

 

 

 

 

 

 

changing the P2 card that is the

 

 

 

 

 

 

recording target.

 

 

 

 

 

 

PRESET:

 

 

 

 

 

 

 

Use the unit’s internal time code.

 

 

 

 

 

 

REGEN: For clips recorded on the

 

 

 

 

 

 

 

recording-target P2 card,

 

 

 

 

 

 

 

regenerate the time code as the

 

 

 

 

 

 

 

time code of the clip that has the

 

 

 

 

 

 

 

most recent date and time.

 

 

 

 

 

 

Notes

 

 

 

 

 

 

Set the date and time accurately. For

 

 

 

 

 

 

guidance on setting, see [Setting the

 

 

 

 

 

 

Internal Clock’s Date and Time]

 

 

 

 

 

 

(page 67).

 

 

 

 

 

 

During operation in either 24P or 24PA

 

 

 

 

 

 

mode, regeneration of the value of the

 

 

 

 

 

 

card recorded in drop-frame is not

 

 

 

 

 

 

permitted.

C

U

F

 

 

 

P.OFF LCD

ON

For selecting whether to allow the time

DISPLAY

OFF

code of the LCD monitor to be set and

 

 

 

 

 

 

the counter to be displayed when the

 

 

 

 

 

 

power is off.

 

 

 

 

 

 

ON:

It is possible to set the time code

 

 

 

 

 

 

 

and display the counter when

 

 

 

 

 

 

OFF:

the power is off.

 

 

 

 

 

 

Power-down LCD monitor while

 

 

 

 

 

 

 

camera power is turned off.

 

 

 

 

 

 

 

Setting and indication disabled.

C

U

F

 

 

 

TC

OUT

TCG

Select the time code to be output to the

 

 

 

 

 

TCG/TCR

time code output connector.

 

 

 

 

 

 

TCG:

Always output time code

 

 

 

 

 

 

 

generator value.

 

 

 

 

 

 

TCG/TCR:

 

 

 

 

 

 

 

Output time code generator

 

 

 

 

 

 

 

value in recording mode, and

 

 

 

 

 

 

 

time code reader value in

 

 

 

 

 

 

 

playback mode.

C

U

F

 

 

 

 

Items/

Adjustable

 

Remarks

Data Saved

Range

 

 

 

TC DISP SEL

30F

Select the display format for the time

 

 

 

 

 

24F

code frame digits. (For 1080-59.94i only)

 

 

 

 

 

 

For details, refer to [Recording time code

 

 

 

 

 

 

and user bits] (page 64).

 

 

 

 

 

 

30F:

Display time code frame digits in

 

 

 

 

 

 

24F:

30 frames.

 

 

 

 

 

 

Convert time code frame digits

 

 

 

 

 

 

 

into 24 frames for display.

C

U

F

 

 

 

TC

VIDEO

0

For setting to correct the time code

SYNCHRO

1

according to the delay of video signals.

 

 

 

 

 

2

0:

Do not correct.

 

 

 

 

 

3

 

 

 

 

 

1:

To delay the time code to be

 

 

 

 

 

 

 

 

 

 

 

 

 

input according to the timing of

 

 

 

 

 

 

2:

the video images.

 

 

 

 

 

 

To forward the time code to be

 

 

 

 

 

 

 

output according to the timing of

 

 

 

 

 

 

3:

the video images.

 

 

 

 

 

 

To delay the time code to be

 

 

 

 

 

 

 

input and forward the time code

 

 

 

 

 

 

 

to be output, respectively,

 

 

 

 

 

 

 

according to the timing of the

 

 

 

 

 

 

 

video images.

 

 

 

 

 

 

For details, refer to [Externally Locking

 

 

 

 

 

 

the Time Code] (page 69).

C

U

F

 

 

 

REC REVIEW

ON

For selecting whether the time code is

REGEN

OFF

regenerated to the value on the P2 card

 

 

 

 

 

 

or not, when subsequent recording starts

 

 

 

 

 

 

after setting the RET SW item on the

 

 

 

 

 

 

<SW MODE> screen to “R.REVIEW”

 

 

 

 

 

 

and pressing the RET button on the lens

 

 

 

 

 

 

or the user button on the unit on which

 

 

 

 

 

 

the RET SW function is assigned.

 

 

 

 

 

 

ON:

The time code is regenerated.

 

 

 

 

 

 

OFF:

The time code is not

 

 

 

 

 

 

 

regenerated.

C

U

F

 

 

 

UMID SET/INFO

 

Items/

Adjustable

Remarks

Data Saved

Range

 

COUNTRY

NO-INFO

Input the user’s country. “NO-INFO” is

 

 

 

 

 

 

displayed until the input completes.

C

U

F

 

 

ORGANIZATION

NO-INFO

Input the user’s organization or company

 

 

 

 

 

 

name. “NO-INFO” is displayed until the

 

 

 

 

 

 

input completes.

C

U

F

 

 

USER

NO-INFO

Input the user name. “NO-INFO” is

 

 

 

 

 

 

displayed until the input completes.

C

U

F

 

 

DEVICE NODE

 

Indicate the product ID number.

 

 

Note

Please refer to [Setting UMID Information] (page 74) for the UMID information setting.

200 Menu: Menu Description Tables