LCD display | The HUMID display lights. |
| Even after condensation detection has |
| been released, it will continue to flash |
| once a second for the next 80 minutes. |
|
|
WARNING lamp | The lamp lights when condensation has |
| been detected. |
|
|
Tally lamp | The lamp flashes four times a second. |
|
|
Warning alarm | Operation differs depending on the setting |
| selected for HUMID OPE on the setting |
| menu. |
| OWhen the ON setting has been selected, |
| the alarm sounds four times a second |
| while recording is being performed. |
| When recording is not being performed, |
| it sounds continuously. |
| OWhen the OFF setting has been |
| selected, the alarm does not sound. |
|
|
Viewfinder | The HUMID display lights for 3 seconds. |
|
|
What the warning | Condensation has formed. |
indicates |
|
VTR unit’s operation The VTR unit’s operation differs depending on the setting selected for HUMID OPE on the setting menu.
O When the ON setting has been selected, the VTR unit continues to operate.
O When the OFF setting has been selected, the VTR unit continues with the recording, but this operation will stop if the tape sticks. Operation stops immediately when an operation other than recording is being performed.
For 80 minutes after condensation detection is released, the drum will rotate however no other operation is possible.
Remedial action Stop the tape travel, and turn off the power. If the HUMID display fails to go off even when the power is turned off and back on, wait until it goes off.
$ TAPE NEAR ENDLCD display | This segment flashes. |
TAPE |
|
E | F |
WARNING lamp | The lamp flashes once a second (during |
| recording). |
|
|
Tally lamp | The lamp flashes once a second (during |
| recording). |
|
|
Warning alarm | The alarm sounds once a second (during |
| recording). |
| This can be switched on the setting menu. |
|
|
Viewfinder | OThe remaining tape display flashes |
| once a second (in the |
| OThe SAVE lamp flashes in tandem with |
| the warning alarm (when SAVE&TAPE |
| has been selected as the setting for the |
| SAVE LED item on the VTR VF |
| INDICATOR screen of VTR MENU). |
| O“=” flashes once a second (three |
| seconds during recording). |
|
|
What the warning | The tape is approaching its end. |
indicates |
|
|
|
VTR unit’s operation | The VTR unit continues to operate. |
|
|
Remedial action | Replace the cassette tape if necessary. |
LCD display | All the segments flash. |
| TAPE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| E | F | |||||||||||||||
|
| |||||||||||||||||
WARNING lamp | The lamp lights (during stop and in the | |||||||||||||||||
| standby OFF mode). |
|
|
| ||||||||||||||
|
|
|
|
| ||||||||||||||
Tally lamp | The lamp flashes 4 times a second |
|
|
| ||||||||||||||
| (during stop and in the standby OFF |
|
|
| ||||||||||||||
| mode). |
|
|
| ||||||||||||||
|
| |||||||||||||||||
Warning alarm | The alarm sounds continuously (during | |||||||||||||||||
| stop and in the standby OFF mode). |
|
|
| ||||||||||||||
|
| |||||||||||||||||
Viewfinder | OThe SAVE lamp flashes four times a | |||||||||||||||||
| second during stop and in the standby | |||||||||||||||||
| OFF mode (when SAVE&TAPE has | |||||||||||||||||
| been selected as the setting for the | |||||||||||||||||
| SAVE LED item on the VTR VF |
|
|
| ||||||||||||||
| INDICATOR screen of VTR MENU). | |||||||||||||||||
| O“=” lights (during stop and in the |
|
|
| ||||||||||||||
| standby OFF mode). |
|
|
| ||||||||||||||
|
|
|
|
| ||||||||||||||
What the warning | The tape has come to its end. |
|
|
| ||||||||||||||
indicates |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VTR unit’s operation If recording, playback or fast forwarding is in progress, the operation is stopped.
Remedial action | Rewind the tape. |
| Alternatively, replace the cassette tape. |
LCD display |
| E | F | |||||||||||
| BATT | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| This segment flashes. | |||||||
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WARNING lamp | The lamp flashes once a second. |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tally lamp | The lamp flashes once a second. |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Warning alarm | The alarm sounds four times a second. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Viewfinder | The BATT display flashes once a second. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
What the warning | The battery is near the end of its charge. | |||||||||||||
indicates |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VTR unit’s operation The VTR unit continues to operate.
Remedial action Replace the battery if necessary.
$BATTERY ENDLCD display |
| E | F | ||||||||||||||
| BATT | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
| All the segments flash. |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WARNING lamp | The lamp lights. |
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tally lamp | The lamp flashes once a second. |
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Warning alarm | The alarm sounds continuously. |
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Viewfinder | The BATT display lights. |
|
|
What the warning The battery is at the end of its charge. indicates
VTR unit’s operation All operation is stopped and the tape is unloaded.
Only cassette eject operation is possible.
Remedial action | Replace the battery. |
127