Panasonic MINAS A3 Series manual Parameter Name Setting Unit Function/Description, Disturbance

Models: MINAS A3 Series

1 24
Download 24 pages 55.34 Kb
Page 19
Image 19

[Connections and Settings in Torque Control Mode]

 

 

 

 

 

 

 

 

 

Default setting is shown by [ ]

Parameter

 

Parameter Name

Setting

Unit

 

 

 

 

Function/Description

No.

 

range

 

 

 

 

 

 

 

 

 

 

 

 

 

27

Disturbance

0 –255

 

Cut-off frequency of the filter for disturbance torque observer is set.

 

torque observer

 

 

 

 

 

 

 

 

 

 

 

 

Set value

 

 

Cutoff Frequency

 

 

filter selection

 

 

 

[0]*

 

 

Disturbance Observer Disabled

 

 

 

 

 

 

 

1 – 255

 

Enabled, filter cutoff frequency [Hz] = 3.7 x setting

 

 

 

 

 

 

 

 

 

 

A larger value provides stronger disturbance suppression; but a larger operation noise is emitted. When using this

 

 

 

function, it is necessary to set Pr20 inertia ratio correctly. When Pr.21 real time auto tuning mode setting is altered,

 

 

 

Pr27 changes to 0(disabled). Also, while the real time auto tuning is enabled (Pr21 is not 0 or 7), Pr27 is fixed to 0

 

 

 

and the disturbance observer is disabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

2nd notch

100 – 1500

Hz

 

• Defines the notch frequency of the second resonance suppression notch

 

frequency

[1500]

 

 

filter.

 

 

 

 

 

 

 

 

 

• The unit is [Hz]. Match the notch frequency with the machine's reso-

 

 

 

 

 

 

nance frequency.

 

 

 

 

 

 

 

 

 

100 to 1499: Filter enabled 1500: Filter disabled

 

 

 

 

 

 

 

 

29

2nd notch width

0 – 4

 

• Select the notch width of the second resonance suppression notch filter.

 

selection

[2]

 

 

• Increasing the set value enlarges the notch width.

 

 

 

 

 

 

 

 

2A

2nd notch depth

0 – 99

 

• Select the notch depth of the second resonance suppression notch filter.

 

selection

[0]

 

 

• Increasing the set value reduces the notch depth and the phase delay.

 

 

 

 

 

 

2F

Adaptive filter

0 – 64

 

• Table No. corresponding to the frequency of the applied filter is dis-

 

frequency

[0]*

 

 

played. (See page 196)

 

 

 

 

 

 

• When the applied filter is enabled (when Pr21 (real time auto tuning

 

 

 

 

 

 

mode setting) is 1-3,7), this parameter is set automatically and can not

 

 

 

 

 

 

be altered.

 

 

 

 

 

 

 

 

 

0: Filter disabled

1 - 64: Filter enabled

 

 

 

 

 

 

Before using this function, see page 196 “Disabling of auto tuning func-

 

 

 

 

 

 

tion” in adjustments.

 

 

 

 

 

 

 

 

• When the applied filter is enabled, the parameter is stored in the EE-

 

 

 

 

 

 

PROM every 30 minutes. And when the applied filter is enabled at turn-

 

 

 

 

 

 

ing ON the power next time, the data stored in the EEPROM is used as

 

 

 

 

 

 

the initial value to adapt the operation.

 

 

 

 

 

 

• When clearing the parameter to reset the adapted operation due to un-

 

 

 

 

 

 

satisfactory operation, once set the applied filter disabled (set Pr21 (real

 

 

 

 

 

 

time auto tuning mode setting) to other than 1 - 3, 7), and make it en-

 

 

 

 

 

 

abled again.

 

 

 

 

 

 

 

 

 

• Refer to “Control of Vibration Damping” of Adjustment volume on page 211.

 

 

 

 

 

 

 

 

 

 

 

Torque Control Mode

Connections and Settings in

Note) Standard default setting in [ ] under "Setting range" and marked with * is automatically set during the real time auto gain tuning. To manually change the value, first disable the auto gain tuning feature be seeing page 196 "Disabling of auto tuning function" in Adjustments, and then enter the desired value.

149

Page 19
Image 19
Panasonic MINAS A3 Series manual Parameter Name Setting Unit Function/Description, Disturbance, 2nd notch width