Parameter Setting
Parameters for Switching to 2nd Gains
|
|
|
|
|
|
|
| Default setting is shown by [ ] | |
Parameter | Parameter Name | Setting | Unit |
|
|
| Function/Description | ||
No. | range |
|
|
| |||||
|
|
|
|
|
|
|
| ||
30 | 2nd gain action | 0 – 1 | – | • The parameter selects switching of PI/P operation and the 1st/2nd gain | |||||
| set up |
|
|
| switching. |
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| Setting value | Gain Selection/Switching |
| ||
|
|
|
|
| 0 |
| The 1st Gain (Possible to switch PI/P) *1 |
| |
|
|
|
|
| [1]* |
| Possible to switch the 1st/2nd gain *2 |
| |
|
|
|
| *1 Switching of 1 PI/P operation is done through gain switching input | |||||
|
|
|
|
| (GAIN CN X5 |
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| GAIN input | Operation of speed loop |
|
|
|
|
|
|
| Open with COM– | PI operation |
| |
|
|
|
|
|
| Connect to | P operation |
| |
|
|
|
| *2 For conditions of switching between the 1st and 2nd gains, refer to | |||||
|
|
|
|
| “Adjustment upon switching gain” of Adjustment volume on page 202. | ||||
|
|
|
|
| |||||
3A | Torque control | 0 – 3 | – | • The parameter selects conditions for switching between the 1st and 2nd | |||||
| switching mode |
|
|
| gains in torque control mode. |
|
| ||
|
|
|
| • This is same as Pr31 except parts related to position and speed control. | |||||
|
|
|
|
|
|
| |||
|
|
|
|
| Setting value | Conditions for Switching Gains |
| ||
|
|
|
|
| [0]* |
| Fixed to the 1st gain. |
|
|
|
|
|
|
| 1 |
| Fixed to the 2nd gain. |
|
|
|
|
|
|
| 2 |
| With the gain switching input (GAIN) turned ON, 2nd gain is |
| |
|
|
|
|
|
| selected. (Pr30 should be set to 1.) |
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
| 3 | *1 | With much variation of torque command, the 2nd gain is |
| |
|
|
|
|
| selected. |
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
| *1 For details on levels to be switched, refer to “Adjustment upon switching | |||||
|
|
|
|
| gain” of Adjustment volume on page 202. | ||||
|
|
|
|
|
|
| |||
3B | Torque control | 0 – 10000 | x 166∝s | • This is same as content of: |
|
| |||
| switching delay time | [0] |
|
| Pr32: Switching delay time |
|
| ||
3C | Torque control | 0 – 20000 | – |
| Pr33: Switching level |
|
| ||
| switching level | [0] |
|
| Pr34: Hysteresis at switching” |
|
| ||
3D | Torque control | 0 – 20000 | – |
| in position control mode. |
|
| ||
| switching hysteresis | [0] |
|
|
|
|
|
|
|
Parameters for Position Control
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Default setting is shown by [ ] | |||||||||||||
Parameter | Parameter Name | Setting |
|
|
|
| Function/Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
No. | range |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
44 | Output pulses per | 1 – 16384 | The parameter sets number of pulses per one revolution of encoder pulse to be out- | |||||||||||||||||||||||||||||
| single turn | [2500] | put to the host device. The pulse will be set in dividing. | |||||||||||||||||||||||||||||
|
|
| You should directly set in this parameter the number of pulses per revolution needed | |||||||||||||||||||||||||||||
|
|
| for your device/system in terms of [Pulse/rev]. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
| |||||||||||||||||||||||||||||
45 | Pulse output | 0 – 1 | In a relationship of phases of output pulse from the rotary encoder, Phase B pulse is | |||||||||||||||||||||||||||||
| logic inversion |
| behind pulse A when the motor rotates in CW direction. (Phase B pulse advances | |||||||||||||||||||||||||||||
|
|
| ahead of phase A pulse, when the motor rotates in CCW direction.) | |||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Inversion of logic of phase B pulse with this parameter could invert a phase |
| ||||||||||||||||||||||||||
|
|
|
|
| relation of phase B pulse to phase A pulse. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| IWhen Motor is Rotating | IWhen Motor is Rotating |
|
| ||||||||||||||||||||||
|
|
|
|
| Setting value |
| in CCW direction | in CW direction |
|
| ||||||||||||||||||||||
|
|
|
|
|
| A pulse(OA) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| [0] | B pulse(OB) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 1 | B pulse(OB) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Inverting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
150