Parameter Setting

Parameters for Switching to 2nd Gains

 

 

 

 

 

 

 

 

Default setting is shown by [ ]

Parameter

Parameter Name

Setting

Unit

 

 

 

Function/Description

No.

range

 

 

 

 

 

 

 

 

 

 

 

30

2nd gain action

0 – 1

• The parameter selects switching of PI/P operation and the 1st/2nd gain

 

set up

 

 

 

switching.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting value

Gain Selection/Switching

 

 

 

 

 

 

0

 

The 1st Gain (Possible to switch PI/P) *1

 

 

 

 

 

 

[1]*

 

Possible to switch the 1st/2nd gain *2

 

 

 

 

 

*1 Switching of 1 PI/P operation is done through gain switching input

 

 

 

 

 

(GAIN CN X5 27-pin).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAIN input

Operation of speed loop

 

 

 

 

 

 

 

Open with COM–

PI operation

 

 

 

 

 

 

 

Connect to COM–.

P operation

 

 

 

 

 

*2 For conditions of switching between the 1st and 2nd gains, refer to

 

 

 

 

 

“Adjustment upon switching gain” of Adjustment volume on page 202.

 

 

 

 

 

3A

Torque control

0 – 3

• The parameter selects conditions for switching between the 1st and 2nd

 

switching mode

 

 

 

gains in torque control mode.

 

 

 

 

 

 

• This is same as Pr31 except parts related to position and speed control.

 

 

 

 

 

 

 

 

 

 

 

 

Setting value

Conditions for Switching Gains

 

 

 

 

 

 

[0]*

 

Fixed to the 1st gain.

 

 

 

 

 

 

 

1

 

Fixed to the 2nd gain.

 

 

 

 

 

 

 

2

 

With the gain switching input (GAIN) turned ON, 2nd gain is

 

 

 

 

 

 

 

selected. (Pr30 should be set to 1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

*1

With much variation of torque command, the 2nd gain is

 

 

 

 

 

 

selected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 For details on levels to be switched, refer to “Adjustment upon switching

 

 

 

 

 

gain” of Adjustment volume on page 202.

 

 

 

 

 

 

 

3B

Torque control

0 – 10000

x 166s

• This is same as content of:

 

 

 

switching delay time

[0]

 

 

Pr32: Switching delay time

 

 

3C

Torque control

0 – 20000

 

Pr33: Switching level

 

 

 

switching level

[0]

 

 

Pr34: Hysteresis at switching”

 

 

3D

Torque control

0 – 20000

 

in position control mode.

 

 

 

switching hysteresis

[0]

 

 

 

 

 

 

 

Parameters for Position Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default setting is shown by [ ]

Parameter

Parameter Name

Setting

 

 

 

 

Function/Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

Output pulses per

1 – 16384

The parameter sets number of pulses per one revolution of encoder pulse to be out-

 

single turn

[2500]

put to the host device. The pulse will be set in dividing.

 

 

 

You should directly set in this parameter the number of pulses per revolution needed

 

 

 

for your device/system in terms of [Pulse/rev].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

Pulse output

0 – 1

In a relationship of phases of output pulse from the rotary encoder, Phase B pulse is

 

logic inversion

 

behind pulse A when the motor rotates in CW direction. (Phase B pulse advances

 

 

 

ahead of phase A pulse, when the motor rotates in CCW direction.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inversion of logic of phase B pulse with this parameter could invert a phase

 

 

 

 

 

 

relation of phase B pulse to phase A pulse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IWhen Motor is Rotating

IWhen Motor is Rotating

 

 

 

 

 

 

 

Setting value

 

in CCW direction

in CW direction

 

 

 

 

 

 

 

 

A pulse(OA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[0]

B pulse(OB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-inverting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

B pulse(OB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150