Self-diagnosis display

There is a self-diagnosis display located on the side of the projector (p. 15) for automatically displaying the corresponding details when an error or warning occurs.

Self-diagnosis

Details

Remedy

display

 

 

 

 

 

U04

Air filter is blocked

• Clean the air filter unit.

U11

Intake air temperature warning

• Check whether there is sufficient space around the projector.

 

 

• The ambient temperature is too high. Use the

U12

Optical module temperature warning

projector where the ambient temperature is less than

 

 

U13

Lamp ambient temperature warning

40 °C (35 °C in high altitude mode).

U14

Low temperature warning

• The ambient temperature is too low. Use the projector

where the ambient temperature is at least 0 °C.

 

 

 

The ambient temperature is 40 °C or more,

• If 100% brightness is required, use the projector

U15

so light output is being limited to protect the

where the ambient temperature is less than 40 °C

 

projector.

(35 °C in high altitude mode).

U21

Intake air temperature error

• Check whether there is sufficient space around the projector.

 

 

• The ambient temperature is too high. Use the

U22

Optical module temperature error

projector where the ambient temperature is less than

 

 

 

 

U23

Lamp ambient temperature error

40 °C (35 °C in high altitude mode).

U24

Low temperature error

• The ambient temperature is too low. Use the projector

where the ambient temperature is at least 0 °C.

 

 

U41

Lamp 1 operating time warning

 

U42

Lamp 2 operating time warning

• The lamp replacement period has arrived. Replace

U43

Lamp 3 operating time warning

the lamp.

U44

Lamp 4 operating time warning

 

U51

Lamp 1 error

• Lamp has not turned on. Wait for the lamp to cool

U52

Lamp 2 error

down and then turn the power back on. If the lamp

U53

Lamp 3 error

still does not turn on, contact your dealer.

U54

Lamp 4 error

 

U61

Lamp 1 : 2 000 hour operating time exceeded

 

U62

Lamp 2 : 2 000 hour operating time exceeded

• The lamp has exceeded its replacement period.

U63

Lamp 3 : 2 000 hour operating time exceeded

Replace the lamp straight away.

U64

Lamp 4 : 2 000 hour operating time exceeded

 

U70

Air filter unit not installed

• Install the air filter unit.

U71

Lamp 1 not installed

• Install the lamp. If the error display does not

U72

Lamp 2 not installed

disappear even after you reinstall the lamp, consult

U73

Lamp 3 not installed

your dealer.

U74

Lamp 4 not installed

 

 

AC power supply voltage drop warning (less

• AC power supply voltage input has dropped. Check

U81

that there is sufficient electrical wiring capacity for the

than 99 V)

 

projector’s power consumption requirements.

 

 

 

 

 

U91

Lamp unit cover is not closed

• Close the lamp unit cover.

 

 

 

H01

Internal clock battery replacement

• The battery needs to be replaced. Consult your

dealer.

 

 

H11

Air intake temperature sensor error

 

 

 

 

H12

Optical module temperature sensor error

 

H13

Lamp ambient temperature sensor error

 

 

 

 

H18

Clogged filter sensor error

 

 

 

• The internal circuitry is not working properly. If turning

F11

Shutter error

the main power off and back on again does not clear

F12

Dynamic iris error

the error display, consult your dealer.

 

 

F13

Air filter unit error

 

 

 

 

F21

2.5 V DC error

 

F22

3.3 V DC error

 

 

 

 

F23

5.0 V DC error

 

 

 

 