External Program Timer
The internal timer can be changed to the specified timer
previously programmed by the input from the external
timer. This function is enabled, when a contact is connect-
ed with pin 22 of the ALARM port.
This item lets you enable or disable the external timer for
recording.
1. Move the cursor to the EXT REC MODE parameter in
the TIMER REC SETUP menu by pressing the Dor C
button.
2. Select the desired program to be changed by pressing
the +or -button.
PROG1 - 4: Selects a timer assigned program number.
---
:Disables the external program timer.
The factory default setting is
---
.
3. Press the SET button to display the assigned program
number menu previously programmed.
If the program number menu has not been edited previ-
ously, edit the assigned program number menu as
described before.
4. Press the SETUP/ESC button to return to the previous
setup menu.
Time Lapse Recording (InternalTimer)
These items let you set the recording parameters for Time
Lapse Recording assigned in the program number menu.
(Continued from Program Timer)
1. Select the recording mode T/L in the program number
menu by pressing the +or -button, then press the
SET button.
The selected Time Lapse Recording menu shown
below appears on the monitor screen.
2. Move the cursor to the TIMER REC MODE parameter in
the menu by pressing the Dor Cbutton.
3. Select the recording time mode to be set by pressing
the +or -button.
OFF: Disables normal recording and enables only
alarm recording.
SF-✽✽H or SF-A*✽✽H: Selects the recording time
mode in enhanced fine quality.
FQ-✽✽H or FQ-A*✽✽H: Selects the recording time
mode in fine quality.
NQ-✽✽H or NQ-A*✽✽H: Selects the recording time
mode in normal quality.
EX-✽✽H or EX-A*✽✽H: Selects the recording time
mode in extended quality.
SP or SP-A*: Freely selectable
✽✽ indicates the hours for recording time mode:
2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480,
720, 960, 1200, 1440, 2160, 2880, 3600, 4320,
6480, 8640
(parameter A* indicates recording with audio)
When the parameter SF/FQ/NQ/EX is selected for
recording time, the recording rate and quality are auto-
matically set according to the selected recording time.
Note: It may not be possible to set the recording time,
depending on the remaining storage capacity of the
hard disk.
The factory default setting is SF-24H.
4. If the parameter SP is selected for recording time, move
the cursor to the REC RATE parameter by pressing the
Dor Cbutton, then select a recording rate by pressing
the +or -button.
1 - 60FPS: Records the selected number of freeze
images every second.
0.5FPS: Records a freeze image every 2 seconds.
0.4FPS: Records a freeze image every 2.5 seconds.
0.3FPS: Records a freeze image every 3.3 seconds.
0.2FPS: Records a freeze image every 5 seconds.
0.1FPS: Records a freeze image every 10 seconds.
Notes:
The maximum recording rate depends on the
selected parameters in the COMMON SETUP menu
as shown in the table.
FIELD/FRAME CAMERA GENLOCK REC RATE
FIELD ON 60FPS
OFF 30FPS
FRAME 3DIM ON 10FPS
ON OFF 10FPS
FRAME 3DIM ON 30FPS
OFF OFF 15FPS
3-1-1-1 PROG1-NO1-G1 REC SETUP
T/L(TIME LAPSE)
TIMER REC MODE SF- 24H
REC RATE 7.5FPS
QUALITY SUPER FINE
TRIGGER ACTION REC+ALM
EVENT REC MODE SF- 24H
REC RATE(MAX) 7.5FPS
REC QUALITY SUPER FINE
DURATION 10S
DYNAMIC REC OFF
REC RATE(BASE) 1FPS
AUTO COPY OFF