85
Group Multi Sequence
The assigned group camera images can be displayed in
succession on the monitor screen for the specified dura-
tion.
Each sequence step can be displayed as either four screen
segments (quad) or a minimum quantity of the segment
screen, depending on the setting.
Refer to GROUP SEQ MODE in the 5 - 1 SEQUENCE
SETUP for further details.
1. Select one of the group displays by pressing the
GROUP SELECT button.
Pressing this button toggles the group display on the
monitor as shown below.
G1: Group 1
G2: Group 2
G3: Group 3
G4: Group 4
none: All Inputs
2. Press the SEQUENCE button to run a sequence on the
monitor screen starting from group 1.
The display pattern varies according to the group
assignment and setting, shown below is an example of
monitor displays.
If the cameras are assigned to the group as follows:
Group 1 Cameras 1, 2, 6, 9, 15
Group 2 Cameras 3, 4, 5
Group 3 Cameras 7, 8, 10, 11
Group 4 Cameras 12, 13, 14,16
<MULTI GROUP setting>
<QUAD setting>
GROUP
SELECT 12
915
6
3
5
4 7
10
8
11
12
14
13
16
12
6915
15 3
5
4
7
10
8
11
12
14
13
16
12
96
3. During the sequence, press the SEQUENCE button to
pause the sequence that is being run on the monitor
screen.
The indicator in the button blinks to indicate that the
sequence is paused.
4. Press the SEQUENCE button to restart the sequence
forward from the step that was previously paused by
pressing the SEQUENCE button.
The indicator in the button changes to a steady light.
5. To return to Spot monitoring, select an assigned cam-
era image by pressing one of the numeric buttons that
the indicator in the button lights up.
If you attempt to press any button other than the one
assigned to the group, it will be ignored.
Notes:
• You can also enable the Auto Skip function to skip
any steps when no video signal is present.
(or a screen segment is blacked out on the multi-
screen display.)
Refer to the AUTO SKIP in the 5 - 1 SEQUENCE
SETUP for further details.
• The setting can be adjusted in such a way that the
sequence step for displaying an image on the Spot
Monitor screen in the single spot mode can be
skipped automatically.
(or - on a multi-screen display - the screen segment
is blacked out.)
Refer to the SECRET VIEW in the 5 MULTIPLEXER
SETUP for further details.
SEQUENCE