Control Port Connection

The CONTROL port can be used for controlling the system with the outboard device as shown below.

13

1

25

CONTROL

14

 

 

Pin

Designation

Pin

Designation

No.

No.

 

 

 

 

 

 

1

Group Recording Output

14

Disk Recorder Error

Output

 

 

 

 

2

Manual Recording Output

15

Ground

 

 

 

 

3

Emergency Recording

16

Ground

Output

 

 

 

 

 

 

 

4

Sequence Timing Output

17

Power Failure Detect Input

Time adjustment can be enabled connecting with the external device as shown below.

WJ-HD500B

CONTROL Port

13

 

 

1

25

24

20

14

Time Adjustment Output

The Extension Units are installed in the system for extending its disk capacity.

Connect each thermal error output from the Extension Units with the CONTROL Port on the rear of the WJ- HD500B Disk Recorder as shown below.

The WJ-HD500B will display the warning for thermal error on the monitor.

5

DVD Remain Space

18

Power Failure Proceeding

 

Output

 

Output

6

HDD Remain Space

19

Power Failure Process

Output

Completion Output

 

 

 

 

7

Thermal Error Input

20

Ground

(Extension 1)

 

 

 

 

 

 

 

8

Thermal Error Input

21

Emergency Recording

 

(Extension 2)

 

Input

9

Thermal Error Input

22

Time Adjustment Output

(Extension 3)

 

 

 

 

 

 

 

10

Thermal Error Input

23

Daylight Savings Select

 

(Extension 4)

 

 

11

Thermal Error Input

24

Time Adjustment Input

 

(Extension 5)

 

 

12

Thermal Error Input

25

Ground

 

(Extension 6)

 

 

13

Thermal Error Input (DVD

 

 

Unit)

 

 

Emergency Recording can be enabled receiving the input from the connected external device.

WJ-HD500B

CONTROL Port

13

1

WJ-HD500B

CONTROL Port

13 121110 9 8 7

1

25

14

20

 

Extension Unit #1

Thermal Error Out

G

Extension Unit #2

Thermal Error Out

G

Extension Unit #3

Thermal Error Out

G

Extension Unit #4

Thermal Error Out

G

Extension Unit #5

Thermal Error Out

G

Extension Unit #6

Thermal Error Out

G

25

21

20

14

Terminal board on

 

ERROR OUT

 

 

G

THERMAL

NC

 

the Extension Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

Page 19
Image 19
Panasonic WJ-HD500B manual Control Port Connection