Setting up the Rack

chap3.fm 23 ページ 2008年4月8日 火曜日 午後5時22分

Setting up the Rack

Rack Mounting

Install the recorder into an EIA standard compliant rack.

EIA standard compliant: an EIA-standard 19"rack, depth

product

550 mm or more

(locally procured)

 

Note:

Installation in a rack requires four M5 x 12 screws.

1Remove the 5 rubber feet from the underside of the recorder.

Use a screwdriver to remove the screws holding the rubber feet.

Remove rubber feet

2 Attach the handle for rack mounting bracket to the rack mounting brackets.

Use the four handle fixing screws for rack mounting bracket and washers to secure them.

Handle fixing screws for rack mounting bracket

Washer

Rack mounting bracket

Washer

Handle for rack mounting bracket

3 Attach the rack mounting bracket to both sides of the recorder.

Secure them using the six rack mounting bracket fixing screws.

Rack mounting bracket fixing screws (provided)

4 Install the recorder in the rack.

Secure using the rack mounting screws.

Rack mounting screws (M5 x 12, locally procured)

Important:

Ensure that the temperature inside the rack does not exceed

45ºC {113 ºF}.

During installation, we recommend installing a fan to keep the temperature in the rack below 30 ºC {86 ºF}.

When installing the recorder in the rack, leave a space of

1unit (44 mm {1.73"}) above and below each unit.

Leave space between racks and ensure proper ventilation around the racks.

Handle for rack

mounting bracket

Handle for rack

Rack mounting brackets (provided) mounting bracket