Panasonic WJ-ND400 manual Sensor, switch, Alarm input, Signal ground, Alarm equipment, Relays etc

Models: WJ-ND400

1 60
Download 60 pages 6.87 Kb
Page 37
Image 37
Sensor

ND400_Basic.book 37 ページ 2008年4月8日 火曜日 午後3時59分

About Connectors

Alarm Connectivity

When a signal is input to Alarm Inputs 1 through 32 (Alarm connector pins 1 through 12 and 15 through 25, Alarm/Control connector pins 1 through 9), recording and camera images are shown according to the settings.

When alarm devices such as a buzzer or indicator are installed externally, connect them to the Alarm output (Alarm/Control connector pin 21).

Sensor

 

Door security

 

 

 

 

switch

(Alarm input 1)

(Signal ground)

(Alarm input 17)

 

 

9

14

1

 

 

ALARM

 

 

Alarm equipment

(Signal ground)

13

 

 

 

 

 

 

Relays etc.*

 

 

 

 

*Attached when

 

21

 

 

necessary.

(Alarm output)

ALARM/CONTROL

 

 

 

 