Panasonic WJ-ND400 Terminal for other devices, Alarm/Control, Signal ground Time adjustment input

Models: WJ-ND400

1 60
Download 60 pages 6.87 Kb
Page 34
Image 34
(Signal ground)

ND400_Basic.book 34 ページ 2008年4月8日 火曜日 午後3時59分

About Connectors

Auto Adjustment Time Function Connection 2

When settings menu - [Basic] - [Time & date] - [Auto adjustment time] is set to [Slave]

[Time Adjust Input] is available and the time on the recorder is synchronized with the other devices.

15 minutes before or after the set [Activation time] if a signal output from another device is input to the Adjustment Time I/O, the time on the recorder is set to the [Activation time].

Example:

When the [Activation time] is set to 15:00

A signal is received at 2:50:00 pm Set to 3:00:00 pm

A signal is received at 3:14:45 pm Set to 3:00:00 pm

A signal is received at 3:20:00 pm Time is not adjusted.

Terminal for other devices

(Signal ground)

(Time adjustment input)

13 20

Signal ground

Sensor input

Alarm Input

Alarm reset input

Series recording input

Time adjustment input

Signal ground

Alarm output

Alarm restore output

Front panel LED monitor output

Alarm recording

Recording

Disk

 

 

 

Buzzer output

System error output

Temperature warning output

Time adjustment output

Series recording output

ALARM/CONTROL

Important:

When [Auto adjustment time] is set to [Slave], time adjustment is not performed during emergency recording and event recording.

Connectivity for Control Output

Connecting alarm equipment like the buzzer and indicator to pins 15 to 18 sounds the buzzer, lights the indicator and indicates operating status when a signal is output.

An example of HDD error output (pin 16) is shown below.

(Signal ground)

 

(HDD error output)

13

16

Alarm equipment

 

 

 

Relays etc.*

ALARM/CONTROL

*Attached when necessary.

 

34

Page 34
Image 34
Panasonic WJ-ND400 manual Terminal for other devices, Alarm/Control, Signal ground Time adjustment input, HDD error output